UGS : 3961db5718de Catégorie :
EP MVS CB 800A 50KA 4P MDO ETV2 DRAWOUT

805.248,30DZD

UGS : 3961db5718de

Spécificités essentielles

Produits associés

Options et accessoires compatibles

Description du pruit
Référence :

MVS08N4MW2V Marque : Schneider Disponibilité : En Stock



  • MVS08N4MW2V
  • Characteristics
  • EP MVS CB 800A 50kA 4P MDO ETV2 drawout
  • manual Circuit breaker
  • Main
  • Range of product EasyPact MVS
  • Range EasyPact
  • Product name MVS08N
  • Device short name MVS08N
  • Product or component type Circuit breaker
  • Device application Distribution
  • Poles description 4P
  • Protected poles description 4P 4d
  • Neutral position Left
  • Network type AC
  • Breaking capacity code N
  • Suitability for isolation Yes conforming to IEC 60947-2
  • Utilisation category Category B
  • Trip unit name ETV2I
  • Trip unit technology Electronic
  • Trip unit rating 800 A (-5...70 °C)
  • Complementary
  • Network frequency 50/60 Hz
  • Control type Manually operated
  • Mounting mode Drawout
  • Mounting support Base plate
  • Rail
  • Connection position Horizontal
  • Vertical
  • Location of connection Rear
  • [In] rated current 800 A (40 °C)
  • [Ui] rated insulation voltage 1000 V AC 50/60 Hz conforming to IEC 60947-2
  • Jun 12, 2017
  • 1
  • Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
  • [Uimp] rated impulse withstand voltage 12 kV conforming to IEC 60947-2
  • [Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
  • Circuit breaker CT rating 800 A
  • Breaking capacity 50 kA (Icu) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
  • [Ics] rated service breaking capacity 50 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
  • Mechanical durability 20000 cycles (with maintenance) conforming to IEC 60947-2
  • 10000 cycles (without maintenance) conforming to IEC 60947-2
  • Electrical durability 6000 cycles (without maintenance), category B at 440 V AC 50/60 Hz, conforming to IEC 60947-2
  • 4000 cycles (without maintenance), category B at 690 V AC 50/60 Hz, conforming to IEC 60947-2
  • Connection pitch 115 mm (without spreader)
  • Contact position indicator Yes
  • [Icm] rated short-circuit making 105 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
  • capacity
  • [Icw] rated short-time withstand current 50 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
  • 42 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2
  • 25 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2
  • Neutral protection setting Without protection (3d)
  • 0.5 x Ir (3d + N/2)
  • 1 x Ir (4d)
  • Trip unit protection functions LI
  • Protection type Instantaneous short-circuit protection
  • Overload protection (long time)
  • Fault indication Overload
  • Short-circuit
  • Internal fault
  • Long time pick-up adjstment type Ir Adjustable 9 settings
  • Long time pick-up adjustment range 0.4...1 x In
  • Long time delay adjustment type Adjustable 9 settings
  • [Tr] long-time delay adjustment 0.5...24 s (6 x Ir)
  • Thermal memory 20 minutes before and after tripping
  • Instantaneous pick-up adjustment type Adjustable 9 settings
  • Ii
  • Instantaneous pick-up adjustment 1.5...10 x Ir
  • range
  • Zone selective interlocking ZSI With
  • Display type Digital display
  • Type of measurement Voltage
  • Current sensor rating range 400/2000 A
  • Maximum breaking time 25 ms
  • Closing response time < 70 ms
  • Height 439 mm
  • Width 556 mm
  • Depth 395 mm
  • Product weight 85 kg
  • Environment
  • Standards IEC 60947-2
  • Product certifications CCC
  • GOST
  • IEC
  • CCS
  • IP degree of protection IP40
  • Pollution degree 4 conforming to IEC 60664-1
  • Ambient air temperature for operation -5...70 °C
  • Ambient air temperature for storage -40...85 °C (without control unit)
  • -25...85 °C (with control unit)
  • 2
  • Offer Sustainability
  • Sustainable offer status Green Premium product
  • RoHS (date code: YYWW) Compliant  - since  1440  -  Schneider Electric declaration of conformity
  • Schneider Electric declaration of conformity
  • REACh Reference not containing SVHC above the threshold
  • Reference not containing SVHC above the threshold
  • Product environmental profile Available
  • Product environmental
  • Product end of life instructions Available
  • End of life manual
  • Contractual warranty
  • Warranty period 18 months
  • 3

Produits Similaires

100 000 de références

Trouvez tout ce dont vous avez besoin dans notre catalogue

Livraison adaptée à vos besoins

Nos solutions de livraison fiables et rapides facilitent votre quotidien

Des conseils d’expert

Recevez une assistance technique de spécialistes pour soutenir vos projets

12
    12
    Votre panier
    01130
    01130
    1 X 22.549,63DZD = 22.549,63DZD
    01034
    01034
    1 X 27.660,32DZD = 27.660,32DZD
    schneider
    CA2KN22S7
    1 X 4.197,29DZD = 4.197,29DZD
    MVS08H3MW5L
    MVS08H3MW5L
    1 X 734.550,77DZD = 734.550,77DZD
    AB1GI
    AB1GI
    1 X 59,18DZD = 59,18DZD
    A9A15307
    A9A15307
    1 X 3.159,60DZD = 3.159,60DZD
    MVS16H3MF2L
    MVS16H3MF2L
    1 X 515.596,11DZD = 515.596,11DZD
    01210
    01210
    1 X 1.268,55DZD = 1.268,55DZD
    schneider
    CA2KN22F72
    1 X 4.259,02DZD = 4.259,02DZD
    CA2KN22F7
    CA2KN22F7
    1 X 3.788,71DZD = 3.788,71DZD
    XS630B1PBL2
    XS630B1PBL2
    1 X 8.167,16DZD = 8.167,16DZD
    MVS08N3NF5L
    MVS08N3NF5L
    1 X 574.521,38DZD = 574.521,38DZD