UGS : d13840d0b6cb Catégorie :
EP MVS CB 1000A 50KA 3P MF ET2 FIXED MAN

500.864,80DZD

UGS : d13840d0b6cb

Spécificités essentielles

Produits associés

Options et accessoires compatibles

Description du pruit
Référence :

MVS10N3MF2L Marque : Schneider Disponibilité : En Stock



  • MVS10N3MF2L
  • Characteristics
  • EP MVS CB 1000A 50kA 3P MF ET2 fixed
  • manual circuit breaker
  • Main
  • Range of product EasyPact MVS
  • Range EasyPact
  • Product name MVS10N
  • Device short name MVS10N
  • Product or component type Circuit breaker
  • Device application Distribution
  • Poles description 3P
  • Protected poles description 3P 3d
  • Network type AC
  • Breaking capacity code N
  • Suitability for isolation Yes conforming to IEC 60947-2
  • Utilisation category Category B
  • Trip unit name ET2I
  • Trip unit technology Electronic
  • Trip unit rating 1000 A (-5...70 °C)
  • Complementary
  • Network frequency 50/60 Hz
  • Control type Manually operated
  • Mounting mode Fixed
  • Mounting support Base plate
  • Rail
  • Connection position Horizontal
  • Vertical
  • Location of connection Rear
  • [In] rated current 1000 A (40 °C)
  • [Ui] rated insulation voltage 1000 V AC 50/60 Hz conforming to IEC 60947-2
  • [Uimp] rated impulse withstand voltage 12 kV conforming to IEC 60947-2
  • Jun 12, 2017
  • 1
  • Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
  • [Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
  • Circuit breaker CT rating 1000 A
  • Breaking capacity 50 kA (Icu) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
  • [Ics] rated service breaking capacity 50 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
  • Mechanical durability 20000 cycles (with maintenance) conforming to IEC 60947-2
  • 10000 cycles (without maintenance) conforming to IEC 60947-2
  • Electrical durability 6000 cycles (without maintenance), category B at 440 V AC 50/60 Hz, conforming to IEC 60947-2
  • 4000 cycles (without maintenance), category B at 690 V AC 50/60 Hz, conforming to IEC 60947-2
  • Connection pitch 115 mm (without spreader)
  • Contact position indicator Yes
  • [Icm] rated short-circuit making 105 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
  • capacity
  • [Icw] rated short-time withstand current 50 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
  • 42 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2
  • 25 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2
  • Trip unit protection functions LI
  • Protection type Instantaneous short-circuit protection
  • Overload protection (long time)
  • Fault indication Overload
  • Short-circuit
  • Internal fault
  • Long time pick-up adjstment type Ir Adjustable 9 settings
  • Long time pick-up adjustment range 0.4...1 x In
  • Long time delay adjustment type Adjustable 9 settings
  • [Tr] long-time delay adjustment 0.5...24 s (6 x Ir)
  • Thermal memory 20 minutes before and after tripping
  • Instantaneous pick-up adjustment type Adjustable 9 settings
  • Ii
  • Instantaneous pick-up adjustment 1.5...10 x Ir
  • range
  • Zone selective interlocking ZSI With
  • Current sensor rating range 400/2000 A
  • Maximum breaking time 25 ms
  • Closing response time < 70 ms
  • Height 352 mm
  • Width 422 mm
  • Depth 297 mm
  • Product weight 40 kg
  • Environment
  • Standards IEC 60947-2
  • Product certifications CCC
  • GOST
  • IEC
  • CCS
  • IP degree of protection IP40
  • Pollution degree 4 conforming to IEC 60664-1
  • Ambient air temperature for operation -5...70 °C
  • Ambient air temperature for storage -40...85 °C (without control unit)
  • -25...85 °C (with control unit)
  • Offer Sustainability
  • Sustainable offer status Not Green Premium product
  • RoHS (date code: YYWW) Will be compliant  on  2Q2016
  • Will be compliant  on  2Q2016
  • REACh Reference not containing SVHC above the threshold
  • 2
  • Reference not containing SVHC above the threshold
  • Product environmental profile Available
  • Product environmental
  • Product end of life instructions Available
  • End of life manual
  • Contractual warranty
  • Warranty period 18 months
  • 3

Produits Similaires

100 000 de références

Trouvez tout ce dont vous avez besoin dans notre catalogue

Livraison adaptée à vos besoins

Nos solutions de livraison fiables et rapides facilitent votre quotidien

Des conseils d’expert

Recevez une assistance technique de spécialistes pour soutenir vos projets

13
    13
    Votre panier
    01104
    01104
    1 X 2.157,07DZD = 2.157,07DZD
    NSYTRAP23
    NSYTRAP23
    1 X 49,46DZD = 49,46DZD
    XC1AC136
    XC1AC136
    1 X 19.423,92DZD = 19.423,92DZD
    NSYCRN44200P
    NSYCRN44200P
    1 X 11.453,31DZD = 11.453,31DZD
    MVS10N3MF2L
    MVS10N3MF2L
    1 X 500.864,80DZD = 500.864,80DZD
    TRV00870
    TRV00870
    1 X 9.386,85DZD = 9.386,85DZD
    KNT63ZT1
    KNT63ZT1
    1 X 5.226,63DZD = 5.226,63DZD
    CA2KN22U72
    CA2KN22U72
    1 X 4.743,75DZD = 4.743,75DZD
    13506
    13506
    1 X 0,00DZD = 0,00DZD
    TRV00880
    TRV00880
    1 X 5.930,02DZD = 5.930,02DZD
    XC1AC147
    XC1AC147
    1 X 27.669,33DZD = 27.669,33DZD
    NSYCRN88300T
    NSYCRN88300T
    1 X 59.590,39DZD = 59.590,39DZD