Nos marques

Tous les produits Schneider

Produits récemment consultés

16015

525,47DZD

04946

22.778,91DZD

08003

45.197,41DZD

MVS10N3MF5L

UGS : efd879033463 Catégorie :
EP MVS CB 1000A 50KA 3P MF ET5 FIXED MAN

500.864,80DZD

UGS : efd879033463

Spécificités essentielles

Produits associés

Options et accessoires compatibles

Référence :

MVS10N3MF5L Marque : Schneider Disponibilité : En Stock



  • MVS10N3MF5L
  • Characteristics
  • EP MVS CB 1000A 50kA 3P MF ET5 fixed
  • manual circuit breaker
  • Main
  • Range of product EasyPact MVS
  • Range EasyPact
  • Product name MVS10N
  • Device short name MVS10N
  • Product or component type Circuit breaker
  • Device application Distribution
  • Poles description 3P
  • Protected poles description 3P 3d
  • Network type AC
  • Breaking capacity code N
  • Suitability for isolation Yes conforming to IEC 60947-2
  • Utilisation category Category B
  • Trip unit name ET5S
  • Trip unit technology Electronic
  • Trip unit rating 1000 A (-5...70 °C)
  • Complementary
  • Network frequency 50/60 Hz
  • Control type Manually operated
  • Mounting mode Fixed
  • Mounting support Base plate
  • Rail
  • Connection position Horizontal
  • Vertical
  • Location of connection Rear
  • [In] rated current 1000 A (40 °C)
  • [Ui] rated insulation voltage 1000 V AC 50/60 Hz conforming to IEC 60947-2
  • [Uimp] rated impulse withstand voltage 12 kV conforming to IEC 60947-2
  • Jun 12, 2017
  • 1
  • Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
  • [Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
  • Circuit breaker CT rating 1000 A
  • Breaking capacity 50 kA (Icu) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
  • [Ics] rated service breaking capacity 50 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
  • Mechanical durability 20000 cycles (with maintenance) conforming to IEC 60947-2
  • 10000 cycles (without maintenance) conforming to IEC 60947-2
  • Electrical durability 6000 cycles (without maintenance), category B at 440 V AC 50/60 Hz, conforming to IEC 60947-2
  • 4000 cycles (without maintenance), category B at 690 V AC 50/60 Hz, conforming to IEC 60947-2
  • Connection pitch 115 mm (without spreader)
  • Contact position indicator Yes
  • [Icm] rated short-circuit making 105 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
  • capacity
  • [Icw] rated short-time withstand current 50 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
  • 42 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2
  • 25 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2
  • Trip unit protection functions LSI
  • Protection type Instantaneous short-circuit protection
  • Overload protection (long time)
  • Short time short-circuit protection
  • Fault indication Overload
  • Short-circuit
  • Internal fault
  • Long time pick-up adjstment type Ir Adjustable 9 settings
  • Long time pick-up adjustment range 0.4...1 x In
  • Long time delay adjustment type Adjustable 9 settings
  • [Tr] long-time delay adjustment 0.5...24 s (6 x Ir)
  • Short-time pick-up adjustment type Isd Adjustable 9 settings
  • [Isd] short-time pick-up adjustment 1.5...10 x Ir
  • range
  • Short-time delay adjustment type Adjustable 5 settings
  • [Tsd] short-time delay adjustment 100...400 ms
  • range
  • Instantaneous pick-up adjustment type Adjustable 9 settings
  • Ii
  • Instantaneous pick-up adjustment 2...15 x In
  • range Off
  • Zone selective interlocking ZSI With
  • Current sensor rating range 400/2000 A
  • Maximum breaking time 25 ms
  • Closing response time < 70 ms
  • Height 352 mm
  • Width 422 mm
  • Depth 297 mm
  • Product weight 40 kg
  • Environment
  • Standards IEC 60947-2
  • Product certifications CCC
  • GOST
  • IEC
  • CCS
  • IP degree of protection IP40
  • Pollution degree 4 conforming to IEC 60664-1
  • Ambient air temperature for operation -5...70 °C
  • Ambient air temperature for storage -40...85 °C (without control unit)
  • -25...85 °C (with control unit)
  • 2
  • Offer Sustainability
  • Sustainable offer status Green Premium product
  • RoHS (date code: YYWW) Compliant  - since  1440  -  Schneider Electric declaration of conformity
  • Schneider Electric declaration of conformity
  • REACh Reference not containing SVHC above the threshold
  • Reference not containing SVHC above the threshold
  • Product environmental profile Available
  • Product environmental
  • Product end of life instructions Available
  • End of life manual
  • Contractual warranty
  • Warranty period 18 months
  • 3

Produits Similaires

100 000 de références

Trouvez tout ce dont vous avez besoin dans notre catalogue

Livraison adaptée à vos besoins

Nos solutions de livraison fiables et rapides facilitent votre quotidien

Des conseils d’expert

Recevez une assistance technique de spécialistes pour soutenir vos projets

14
    14
    Votre panier
    KBA40ABT4W
    KBA40ABT4W
    1 X 66.047,21DZD = 66.047,21DZD
    01094
    01094
    1 X 5.767,92DZD = 5.767,92DZD
    01033
    01033
    1 X 28.293,02DZD = 28.293,02DZD
    NSYBDS26
    NSYBDS26
    1 X 1.098,22DZD = 1.098,22DZD
    AB1GJ
    AB1GJ
    1 X 54,04DZD = 54,04DZD
    XC1AC137
    XC1AC137
    1 X 27.251,17DZD = 27.251,17DZD
    NSYTEX8
    NSYTEX8
    1 X 175,85DZD = 175,85DZD
    ZD5PA203
    ZD5PA203
    1 X 2.646,07DZD = 2.646,07DZD
    08128
    08128
    1 X 21.503,37DZD = 21.503,37DZD
    16008
    16008
    1 X 515,14DZD = 515,14DZD
    03002
    03002
    1 X 4.226,84DZD = 4.226,84DZD
    03003
    03003
    1 X 2.255,26DZD = 2.255,26DZD
    AB1GW
    AB1GW
    1 X 56,35DZD = 56,35DZD
    MVS08H3NW6L
    MVS08H3NW6L
    1 X 863.185,06DZD = 863.185,06DZD