Nos marques

Tous les produits Schneider

Produits récemment consultés

PKX32M713

3.351,45DZD

XS608B1PBM12

7.985,26DZD

XS508B1PAM8

6.597,63DZD

MVS10N3NW5V

UGS : 6139c58df3ef Catégorie :
EP MVS CB 1000A 50KA 3P EDO 240VAC ETV5

781.133,82DZD

UGS : 6139c58df3ef

Spécificités essentielles

Produits associés

Options et accessoires compatibles

Référence :

MVS10N3NW5V Marque : Schneider Disponibilité : En Stock



  • MVS10N3NW5V
  • Characteristics
  • EP MVS CB 1000A 50kA 3P EDO 240VAC ETV5
  • drawout electrical circuit breaker
  • Main
  • Range of product EasyPact MVS
  • Range EasyPact
  • Product name MVS10N
  • Device short name MVS10N
  • Product or component type Circuit breaker
  • Device application Distribution
  • Poles description 3P
  • Protected poles description 3P 3d
  • Network type AC
  • Breaking capacity code N
  • Suitability for isolation Yes conforming to IEC 60947-2
  • Utilisation category Category B
  • Trip unit name ETV5S
  • Trip unit technology Electronic
  • Trip unit rating 1000 A (-5...70 °C)
  • Complementary
  • Network frequency 50/60 Hz
  • Control type Electrically operated
  • Mounting mode Drawout
  • Mounting support Base plate
  • Rail
  • Connection position Horizontal
  • Vertical
  • Location of connection Rear
  • [In] rated current 1000 A (40 °C)
  • [Ui] rated insulation voltage 1000 V AC 50/60 Hz conforming to IEC 60947-2
  • [Uimp] rated impulse withstand voltage 12 kV conforming to IEC 60947-2
  • Jun 12, 2017
  • 1
  • Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
  • [Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
  • Circuit breaker CT rating 1000 A
  • Breaking capacity 50 kA (Icu) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
  • [Ics] rated service breaking capacity 50 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
  • Mechanical durability 20000 cycles (with maintenance) conforming to IEC 60947-2
  • 10000 cycles (without maintenance) conforming to IEC 60947-2
  • Electrical durability 6000 cycles (without maintenance), category B at 440 V AC 50/60 Hz, conforming to IEC 60947-2
  • 4000 cycles (without maintenance), category B at 690 V AC 50/60 Hz, conforming to IEC 60947-2
  • Connection pitch 115 mm (without spreader)
  • Contact position indicator Yes
  • [Icm] rated short-circuit making 105 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
  • capacity
  • [Icw] rated short-time withstand current 50 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
  • 42 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2
  • 25 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2
  • Trip unit protection functions LSI
  • Protection type Instantaneous short-circuit protection
  • Overload protection (long time)
  • Short time short-circuit protection
  • Fault indication Overload
  • Short-circuit
  • Internal fault
  • Long time pick-up adjstment type Ir Adjustable 9 settings
  • Long time pick-up adjustment range 0.4...1 x In
  • Long time delay adjustment type Adjustable 9 settings
  • [Tr] long-time delay adjustment 0.5...24 s (6 x Ir)
  • Short-time pick-up adjustment type Isd Adjustable 9 settings
  • [Isd] short-time pick-up adjustment 1.5...10 x Ir
  • range
  • Short-time delay adjustment type Adjustable 5 settings
  • [Tsd] short-time delay adjustment 100...400 ms
  • range
  • Instantaneous pick-up adjustment type Adjustable 9 settings
  • Ii
  • Instantaneous pick-up adjustment 2...15 x In
  • range Off
  • Zone selective interlocking ZSI With
  • Display type Digital display
  • Type of measurement Voltage
  • Current sensor rating range 400/2000 A
  • Maximum breaking time 25 ms
  • Closing response time < 70 ms
  • Height 439 mm
  • Width 441 mm
  • Depth 395 mm
  • Product weight 70 kg
  • Environment
  • Standards IEC 60947-2
  • Product certifications CCC
  • GOST
  • IEC
  • CCS
  • IP degree of protection IP40
  • Pollution degree 4 conforming to IEC 60664-1
  • Ambient air temperature for operation -5...70 °C
  • Ambient air temperature for storage -40...85 °C (without control unit)
  • 2
  • -25...85 °C (with control unit)
  • Offer Sustainability
  • Sustainable offer status Green Premium product
  • RoHS (date code: YYWW) Compliant  - since  1440  -  Schneider Electric declaration of conformity
  • Schneider Electric declaration of conformity
  • REACh Reference not containing SVHC above the threshold
  • Reference not containing SVHC above the threshold
  • Product environmental profile Available
  • Product environmental
  • Product end of life instructions Available
  • End of life manual
  • Contractual warranty
  • Warranty period 18 months
  • 3

Produits Similaires

100 000 de références

Trouvez tout ce dont vous avez besoin dans notre catalogue

Livraison adaptée à vos besoins

Nos solutions de livraison fiables et rapides facilitent votre quotidien

Des conseils d’expert

Recevez une assistance technique de spécialistes pour soutenir vos projets

14
    14
    Votre panier
    GB2CD09
    GB2CD09
    1 X 6.620,44DZD = 6.620,44DZD
    1059180000
    1059180000
    1 X 97,58DZD = 97,58DZD
    LV430785
    LV430785
    1 X 83.903,57DZD = 83.903,57DZD
    ZCMD21L5
    ZCMD21L5
    1 X 8.130,87DZD = 8.130,87DZD
    1059100000
    1059100000
    1 X 97,58DZD = 97,58DZD
    S520266
    S520266
    1 X 0,00DZD = 0,00DZD
    140CRP93200
    140CRP93200
    1 X 193.273,38DZD = 193.273,38DZD
    LV429777
    LV429777
    1 X 53.725,43DZD = 53.725,43DZD
    NSYPPS205
    NSYPPS205
    1 X 23.407,34DZD = 23.407,34DZD
    LV432749
    LV432749
    1 X 162.308,97DZD = 162.308,97DZD
    03652
    03652
    1 X 0,00DZD = 0,00DZD
    XC1AC116
    XC1AC116
    1 X 20.748,08DZD = 20.748,08DZD
    XBTZ9980
    XBTZ9980
    1 X 973,43DZD = 973,43DZD
    MVS08H3MF6L
    MVS08H3MF6L
    1 X 540.148,31DZD = 540.148,31DZD