Nos marques

Tous les produits Schneider

Produits récemment consultés

LC2K0601G72

12.250,12DZD

LC2DT25P7

20.059,88DZD

PKF32F744

4.358,58DZD

LC2D25FL

25.682,76DZD

MVS25N4MW5A

UGS : 04da05eee58b Catégorie :
EP MVS CB 2500A 50KA 4P MDO ETA5 DRAWOUT

1.143.940,05DZD

UGS : 04da05eee58b

Spécificités essentielles

Produits associés

Options et accessoires compatibles

Description du pruit
Référence :

MVS25N4MW5A Marque : Schneider Disponibilité : En Stock



  • MVS25N4MW5A
  • Characteristics
  • EP MVS CB 2500A 50kA 4P MDO ETA5 drawout
  • manual Circuit breaker
  • Main
  • Range of product EasyPact MVS
  • Range EasyPact
  • Product name MVS25N
  • Device short name MVS25N
  • Product or component type Circuit breaker
  • Device application Distribution
  • Poles description 4P
  • Protected poles description 4P 4d
  • Neutral position Left
  • Network type AC
  • Breaking capacity code N
  • Suitability for isolation Yes conforming to IEC 60947-2
  • Utilisation category Category B
  • Trip unit name ETA5S
  • Trip unit technology Electronic
  • Trip unit rating 2500 A (-5...70 °C)
  • Complementary
  • Network frequency 50/60 Hz
  • Control type Manually operated
  • Mounting mode Drawout
  • Mounting support Base plate
  • Rail
  • Connection position Horizontal
  • Vertical
  • Location of connection Rear
  • [In] rated current 2500 A (40 °C)
  • [Ui] rated insulation voltage 1000 V AC 50/60 Hz conforming to IEC 60947-2
  • Jun 12, 2017
  • 1
  • Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
  • [Uimp] rated impulse withstand voltage 12 kV conforming to IEC 60947-2
  • [Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
  • Circuit breaker CT rating 2500 A
  • Breaking capacity 50 kA (Icu) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
  • [Ics] rated service breaking capacity 50 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
  • Mechanical durability 20000 cycles (with maintenance) conforming to IEC 60947-2
  • 10000 cycles (without maintenance) conforming to IEC 60947-2
  • Electrical durability 5000 cycles (without maintenance), category B at 440 V AC 50/60 Hz, conforming to IEC 60947-2
  • 2500 cycles (without maintenance), category B at 690 V AC 50/60 Hz, conforming to IEC 60947-2
  • Connection pitch 115 mm (without spreader)
  • Contact position indicator Yes
  • [Icm] rated short-circuit making 105 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
  • capacity
  • [Icw] rated short-time withstand current 50 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
  • 42 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2
  • 25 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2
  • Neutral protection setting Without protection (3d)
  • 0.5 x Ir (3d + N/2)
  • 1 x Ir (4d)
  • Trip unit protection functions LSI
  • Protection type Instantaneous short-circuit protection
  • Overload protection (long time)
  • Short time short-circuit protection
  • Fault indication Overload
  • Short-circuit
  • Internal fault
  • Long time pick-up adjstment type Ir Adjustable 9 settings
  • Long time pick-up adjustment range 0.4...1 x In
  • Long time delay adjustment type Adjustable 9 settings
  • [Tr] long-time delay adjustment 0.5...24 s (6 x Ir)
  • Short-time pick-up adjustment type Isd Adjustable 9 settings
  • [Isd] short-time pick-up adjustment 1.5...10 x Ir
  • range
  • Short-time delay adjustment type Adjustable 5 settings
  • [Tsd] short-time delay adjustment 100...400 ms
  • range
  • Instantaneous pick-up adjustment type Adjustable 9 settings
  • Ii
  • Instantaneous pick-up adjustment 2...15 x In
  • range Off
  • Zone selective interlocking ZSI With
  • Display type Digital display
  • Type of measurement Current
  • Current sensor rating range 1000/4000 A
  • Maximum breaking time 25 ms
  • Closing response time < 70 ms
  • Height 439 mm
  • Width 556 mm
  • Depth 395 mm
  • Product weight 120 kg
  • Environment
  • Standards IEC 60947-2
  • Product certifications CCC
  • GOST
  • IEC
  • CCS
  • IP degree of protection IP40
  • 2
  • Pollution degree 4 conforming to IEC 60664-1
  • Ambient air temperature for operation -5...70 °C
  • Ambient air temperature for storage -40...85 °C (without control unit)
  • -25...85 °C (with control unit)
  • Offer Sustainability
  • Sustainable offer status Green Premium product
  • RoHS (date code: YYWW) Compliant  - since  1440  -  Schneider Electric declaration of conformity
  • Schneider Electric declaration of conformity
  • REACh Reference not containing SVHC above the threshold
  • Reference not containing SVHC above the threshold
  • Product environmental profile Available
  • Product environmental
  • Product end of life instructions Available
  • End of life manual
  • Contractual warranty
  • Warranty period 18 months
  • 3

Produits Similaires

100 000 de références

Trouvez tout ce dont vous avez besoin dans notre catalogue

Livraison adaptée à vos besoins

Nos solutions de livraison fiables et rapides facilitent votre quotidien

Des conseils d’expert

Recevez une assistance technique de spécialistes pour soutenir vos projets

10
    10
    Votre panier
    BLRCH155A186B48
    BLRCH155A186B48
    1 X 13.703,77DZD = 13.703,77DZD
    16003
    16003
    1 X 7.277,04DZD = 7.277,04DZD
    CA2KN22F7
    CA2KN22F7
    1 X 3.788,71DZD = 3.788,71DZD
    CA2KN22D7
    CA2KN22D7
    1 X 3.788,71DZD = 3.788,71DZD
    CA2KN22V7
    CA2KN22V7
    1 X 4.085,86DZD = 4.085,86DZD
    MVS08N3MW5A
    MVS08N3MW5A
    1 X 671.369,25DZD = 671.369,25DZD
    MVS08N3MW6A
    MVS08N3MW6A
    1 X 725.442,73DZD = 725.442,73DZD
    A9C22015
    A9C22015
    1 X 5.939,65DZD = 5.939,65DZD
    MVS25N4MW5A
    MVS25N4MW5A
    1 X 1.143.940,05DZD = 1.143.940,05DZD
    MVS08N3MW5V
    MVS08N3MW5V
    1 X 703.420,41DZD = 703.420,41DZD