  • MVS32N4NW2A
  • Characteristics
  • EP MVS CB 3200A 50kA 4P EDO 240VAC ETA2
  • drawout electrical circuit breaker
  • Main
  • Range of product EasyPact MVS
  • Range EasyPact
  • Product name MVS32N
  • Device short name MVS32N
  • Product or component type Circuit breaker
  • Device application Distribution
  • Poles description 4P
  • Protected poles description 4P 4d
  • Neutral position Left
  • Network type AC
  • Breaking capacity code N
  • Suitability for isolation Yes conforming to IEC 60947-2
  • Utilisation category Category B
  • Trip unit name ETA2I
  • Trip unit technology Electronic
  • Trip unit rating 3200 A (-5...70 °C)
  • Complementary
  • Network frequency 50/60 Hz
  • Control type Electrically operated
  • Mounting mode Drawout
  • Mounting support Base plate
  • Rail
  • Connection position Horizontal
  • Vertical
  • Location of connection Rear
  • [In] rated current 3200 A (40 °C)
  • [Ui] rated insulation voltage 1000 V AC 50/60 Hz conforming to IEC 60947-2
  • Jun 12, 2017
  • 1
  • Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
  • [Uimp] rated impulse withstand voltage 12 kV conforming to IEC 60947-2
  • [Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
  • Circuit breaker CT rating 3200 A
  • Breaking capacity 50 kA (Icu) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
  • [Ics] rated service breaking capacity 50 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
  • Mechanical durability 20000 cycles (with maintenance) conforming to IEC 60947-2
  • 10000 cycles (without maintenance) conforming to IEC 60947-2
  • Electrical durability 5000 cycles (without maintenance), category B at 440 V AC 50/60 Hz, conforming to IEC 60947-2
  • 2500 cycles (without maintenance), category B at 690 V AC 50/60 Hz, conforming to IEC 60947-2
  • Connection pitch 115 mm (without spreader)
  • Contact position indicator Yes
  • [Icm] rated short-circuit making 105 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
  • capacity
  • [Icw] rated short-time withstand current 50 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
  • 42 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2
  • 25 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2
  • Neutral protection setting Without protection (3d)
  • 0.5 x Ir (3d + N/2)
  • 1 x Ir (4d)
  • Trip unit protection functions LI
  • Protection type Instantaneous short-circuit protection
  • Overload protection (long time)
  • Fault indication Overload
  • Short-circuit
  • Internal fault
  • Long time pick-up adjstment type Ir Adjustable 9 settings
  • Long time pick-up adjustment range 0.4...1 x In
  • Long time delay adjustment type Adjustable 9 settings
  • [Tr] long-time delay adjustment 0.5...24 s (6 x Ir)
  • Thermal memory 20 minutes before and after tripping
  • Instantaneous pick-up adjustment type Adjustable 9 settings
  • Ii
  • Instantaneous pick-up adjustment 1.5...10 x Ir
  • range
  • Zone selective interlocking ZSI With
  • Display type Digital display
  • Type of measurement Current
  • Current sensor rating range 1000/4000 A
  • Maximum breaking time 25 ms
  • Closing response time < 70 ms
  • Height 439 mm
  • Width 556 mm
  • Depth 395 mm
  • Product weight 120 kg
  • Environment
  • Standards IEC 60947-2
  • Product certifications CCC
  • GOST
  • IEC
  • CCS
  • IP degree of protection IP40
  • Pollution degree 4 conforming to IEC 60664-1
  • Ambient air temperature for operation -5...70 °C
  • Ambient air temperature for storage -40...85 °C (without control unit)
  • -25...85 °C (with control unit)
  • 2
  • Offer Sustainability
  • Sustainable offer status Green Premium product
  • RoHS (date code: YYWW) Compliant  - since  1440  -  Schneider Electric declaration of conformity
  • Schneider Electric declaration of conformity
  • REACh Reference not containing SVHC above the threshold
  • Reference not containing SVHC above the threshold
  • Product environmental profile Available
  • Product environmental
  • Product end of life instructions Available
  • End of life manual
  • Contractual warranty
  • Warranty period 18 months
  • 3

Produits Similaires

100 000 de références

Trouvez tout ce dont vous avez besoin dans notre catalogue

Livraison adaptée à vos besoins

Nos solutions de livraison fiables et rapides facilitent votre quotidien

Des conseils d’expert

Recevez une assistance technique de spécialistes pour soutenir vos projets

17
    17
    Votre panier
    12911
    12911
    1 X 519,75DZD = 519,75DZD
    KNA160ZJ4
    KNA160ZJ4
    1 X 13.209,77DZD = 13.209,77DZD
    LC2D115V7
    LC2D115V7
    1 X 109.183,74DZD = 109.183,74DZD
    LP4K1201BW3
    LP4K1201BW3
    1 X 7.138,64DZD = 7.138,64DZD
    NSYCVF560M115PF
    NSYCVF560M115PF
    1 X 61.178,44DZD = 61.178,44DZD
    10501
    10501
    1 X 15.703,20DZD = 15.703,20DZD
    CA2KN22G7
    CA2KN22G7
    1 X 3.788,71DZD = 3.788,71DZD
    LC2D115Q7
    LC2D115Q7
    1 X 109.183,74DZD = 109.183,74DZD
    KBA40ABD4W
    KBA40ABD4W
    1 X 8.159,40DZD = 8.159,40DZD
    K1F003MCH
    K1F003MCH
    1 X 5.671,88DZD = 5.671,88DZD
    LX1D8G7
    LX1D8G7
    1 X 8.498,77DZD = 8.498,77DZD
    18608
    18608
    1 X 67.602,66DZD = 67.602,66DZD
    schneider
    LC1DPK12V7
    1 X 29.702,00DZD = 29.702,00DZD
    schneider
    CA2KN22B72
    1 X 4.085,86DZD = 4.085,86DZD
    CA2KN22V7
    CA2KN22V7
    1 X 4.085,86DZD = 4.085,86DZD
    schneider
    CA2KN22Y7
    1 X 4.334,40DZD = 4.334,40DZD
    VBD01
    VBD01
    1 X 4.966,19DZD = 4.966,19DZD