    Référence : MVS40N3NF6L
    Marque : Schneider
    Disponibilité : En Stock


    Fiche Technique

    Télécharger


    Caractéristiques

    MVS40N3NF6L
    Characteristics
    EP MVS CB 4000A 55kA 3P EF 240VAC ET6
    fixed electrical circuit breaker
    Main
    Range of product EasyPact MVS
    Range EasyPact
    Product name MVS40N
    Device short name MVS40N
    Product or component type Circuit breaker
    Device application Distribution
    Poles description 3P
    Protected poles description 3P 3d
    Network type AC
    Breaking capacity code N
    Suitability for isolation Yes conforming to IEC 60947-2
    Utilisation category Category B
    Trip unit name ET6G
    Trip unit technology Electronic
    Trip unit rating 4000 A (-5…70 °C)
    Complementary
    Network frequency 50/60 Hz
    Control type Electrically operated
    Mounting mode Fixed
    Mounting support Base plate
    Rail
    Connection position Horizontal
    Vertical
    Location of connection Rear
    [In] rated current 4000 A (40 °C)
    [Ui] rated insulation voltage 1000 V AC 50/60 Hz conforming to IEC 60947-2
    [Uimp] rated impulse withstand voltage 12 kV conforming to IEC 60947-2
    Jun 12, 2017
    1
    Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
    [Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
    Circuit breaker CT rating 4000 A
    Breaking capacity 55 kA (Icu) at 220…440 V AC 50/60 Hz conforming to IEC 60947-2
    [Ics] rated service breaking capacity 55 kA (Ics) at 220…440 V AC 50/60 Hz conforming to IEC 60947-2
    Mechanical durability 20000 cycles (with maintenance) conforming to IEC 60947-2
    10000 cycles (without maintenance) conforming to IEC 60947-2
    Electrical durability 5000 cycles (without maintenance), category B at 440 V AC 50/60 Hz, conforming to IEC 60947-2
    2500 cycles (without maintenance), category B at 690 V AC 50/60 Hz, conforming to IEC 60947-2
    Connection pitch 115 mm (without spreader)
    Contact position indicator Yes
    [Icm] rated short-circuit making 121 kA (Icm) at 220…440 V AC 50/60 Hz conforming to IEC 60947-2
    capacity
    [Icw] rated short-time withstand current 42 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2
    55 kA (1 s) at 220…440 V AC 50/60 Hz conforming to IEC 60947-2
    30 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2
    Trip unit protection functions LSIG
    Protection type Earth fault
    Instantaneous short-circuit protection
    Overload protection (long time)
    Short time short-circuit protection
    Fault indication Overload
    Short-circuit
    Internal fault
    Earth fault
    Long time pick-up adjstment type Ir Adjustable 9 settings
    Long time pick-up adjustment range 0.4…1 x In
    Long time delay adjustment type Adjustable 9 settings
    [Tr] long-time delay adjustment 0.5…24 s (6 x Ir)
    Short-time pick-up adjustment type Isd Adjustable 9 settings
    [Isd] short-time pick-up adjustment 1.5…10 x Ir
    range
    Short-time delay adjustment type Adjustable 5 settings
    [Tsd] short-time delay adjustment 100…400 ms
    range
    Instantaneous pick-up adjustment type Adjustable 9 settings
    Ii
    Instantaneous pick-up adjustment 2…15 x In
    range Off
    Ground-fault pick-up adjustment type Adjustable 9 settings
    Ground-fault time delay adjustment Adjustable 5 settings
    type -tg
    [Tg] ground-fault time delay 100…400 ms
    adjustment range
    [Ig] ground-fault pick-up adjustment 500…1200 A
    range
    Zone selective interlocking ZSI With
    Current sensor rating range 1000/4000 A
    Maximum breaking time 25 ms
    Closing response time < 70 ms Height 352 mm Width 422 mm Depth 297 mm Product weight 60 kg Environment Standards IEC 60947-2 Product certifications CCC GOST IEC 2 CCS IP degree of protection IP40 Pollution degree 4 conforming to IEC 60664-1 Ambient air temperature for operation -5...70 °C Ambient air temperature for storage -40...85 °C (without control unit) -25...85 °C (with control unit) Offer Sustainability Sustainable offer status Green Premium product RoHS (date code: YYWW) Compliant  - since  1440  -  Schneider Electric declaration of conformity Schneider Electric declaration of conformity REACh Reference not containing SVHC above the threshold Reference not containing SVHC above the threshold Product environmental profile Available Product environmental Product end of life instructions Available End of life manual Contractual warranty Warranty period 18 months 3

    Produits qui pourraient aussi répondre à vos besoins

    Produits récemment consultés

    Aucun produit récemment consulté à afficher
    références de produits

    100 000 de références

    Trouvez tout ce dont vous avez besoin dans notre catalogue

    livraison rapide

    Livraison adaptée à vos besoins

    Nos solutions de livraison fiables et rapides facilitent votre quotidien

    expert senia electrique

    Des conseils d’expert

    Recevez une assistance technique de spécialistes pour soutenir vos projets

    Panier
    MVS40N3NF6L
    685.006,27DZD
    Retour en haut