RE88857105
UGS : f38e61a4dc07
Catégorie : Schneider
universal plug-in timing relay - 110..240 V AC - 1C/O
UGS :
f38e61a4dc07
Spécificités essentielles
Produits associés
-
Quick ViewLire la suiteDisjoncteurs modulaires sur rail MCB: Acti9 IC60
A9F77416 – Disjoncteur 4P Courbe C Schneider Electric
-
Quick ViewAjouter au panier
-
Quick ViewAjouter au panier
Options et accessoires compatibles
Référence : RE88857105
Marque : Schneider
Disponibilité : En Stock
- RE88857105
- Characteristics
- universal plug-in timing relay - 110..240 V AC - 1
- C/O
- Main
- Range of product Zelio Time
- Product or component type Universal timing relay
- Electrical connection Plug-in sub-base with 11 pin(s)
- Discrete output type Relay
- Contacts type and composition 1 C/O (timed contact)
- Component name RE88857
- Time delay type A
- B
- C
- D
- Di
- H
- Time delay range 3599640 s
- 35996400 s
- 359940 s
- 359964 s
- 5999 s
- 5999.4 s
- 59994 s
- 599940 s
- 9999 s
- 99.99 s
- 999.9 s
- [In] rated current 8 A
- Display type LCD
- Complementary
- Product front plate size 48 x 48 mm
- [Us] rated supply voltage 110...240 V AC
- 24 V AC/DC
- Voltage range 0.85...1.1 Us
- Display digits 4 digit(s) of 8 mm height
- Jun 12, 2017
- 1
- Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
- Housing material Self-extinguishing
- Repeat accuracy +/- 0.03 % +/- 20 ms
- Setting accuracy of time delay +/- 0.03 % +/- 20 ms of full scale
- Minimum pulse duration 50 ms
- Reset time <= 0.05 ms after time delay, on de-energisation
- <= 0.05 ms during time delay, on de-energisation
- Power consumption in VA 1 VA at 24 V
- 11 VA at 220 V
- 3.5 VA at 110 V
- Power consumption in W 0.5 W at 24 V
- Breaking capacity <= 2000 VA for resistive load
- Breaking capacity <= 190 W for resistive load
- Maximum switching voltage 250 V AC
- 30 V DC
- Temporary permissible current 15 A for < 10 s
- Minimum output current 100 mA
- Electrical durability 100000 cycles at 250 V AC for resistive load
- Mechanical durability 5000000 cycles
- Mounting support Base mounted: socket
- Panel mounted: system supplied with the product
- Local signalling None
- Product weight 0.1 kg
- Environment
- Immunity to microbreaks < 30 ms
- Standards IEC 60255
- VDE 0435
- VDE 2021
- Product certifications CSA
- cURus
- Ambient air temperature for storage -30...70 °C
- Ambient air temperature for operation -10...60 °C
- IP degree of protection IP65 (front panel)
- Contractual warranty
- Warranty period 18 months
- 2
- Product data sheet
- RE88857105
- Technical Description
- Function A : Power on Delay Relay
- Description
- The timing period T begins on energisation. After timing, the output(s) R close(s). The second output can be either timed or instantaneous.
- Function: 1 Output
- Function: 2 Outputs
- 2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.)
- 3
- Product data sheet
- RE88857105
- Technical Description
- Function B : Interval Relay with Control Signal
- Description
- After power-up, pulsing or maintaining control contact C starts the timing T. The output R closes for the duration of the timing period T then
- reverts to its initial state.
- Function: 1 Output
- 4
- Product data sheet
- RE88857105
- Technical Description
- Function C : Off-Delay Relay with Control Signal
- Description
- After power-up and closing of the control contact C, the output R closes. When control contact C re-opens, timing T starts. At the end of the timing
- period, the output(s) R revert(s) to its/their initial state. The second output can be either timed or instantaneous.
- Function: 1 Output
- Function: 2 Outputs
- 2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.)
- 5
- Product data sheet
- RE88857105
- Technical Description
- Function D : Symmetrical Flasher Relay (Starting Pulse Off)
- Description
- Repetitive cycle with two timing periods T of equal duration, with output(s) R changing state at the end of each timing period T.
- The second output can be either timed or instantaneous.
- Function: 1 Output
- Function: 2 Outputs
- 2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.)
- 6
- Product data sheet
- RE88857105
- Technical Description
- Function Di : Symmetrical Flasher Relay (Starting Pulse On)
- Description
- Repetitive cycle with two timing periods T of equal duration, with output(s) R changing state at the end of each timing period T.
- The second output can be either timed or instantaneous.
- Function: 1 Output
- Function: 2 Outputs
- 2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.)
- 7
- Product data sheet
- RE88857105
- Technical Description
- Function H : Interval Relay
- Description
- On energisation of the relay, timing period T starts and the output(s) R close(s). At the end of the timing period T, the output(s) R revert(s) to its/
- their initial state. The second output can be either timed or instantaneous.
- Function: 1 Output
- Function: 2 Outputs
- 2 timed outputs (R1/R2) or 1 timed output (R1) and 1 instantaneous output (R2 inst.)
- 8
- Product data sheet
- RE88857105
- Technical Description
- Legend
- Relay de-energised
- Relay energised
- Output open
- Output closed
- C Control contact
- G Gate
- R Relay or solid state output
- R1/R2 2 timed outputs
- R2 inst.The second output is instantaneous if the right position is selected
- T Timing period
- Ta Adjustable On-delay
- Tr Adjustable Off-delay
- U Supply
- 9
- Product data sheet
- RE88857105
- Dimensions Drawings
- Width 48 mm
- 10
- Product data sheet
- RE88857105
- Mounting and Clearance
- Panel Cut-Out
- 11
- Product data sheet
- RE88857105
- Connections and Schema
- Wiring Diagram
- Terminal Referencing
- 1 Another load may be connected
- Internal Wiring Diagram
- 12
Produits Similaires
Produits similaires
Produits récemment consultés
Aucun produit récemment consulté à afficher