XB4BS542
UGS : d6a70e8d788a
Catégorie : Schneider
Red Ø40 Emergency stop, switching off Ø22 latching turn release 1NC
UGS :
d6a70e8d788a
Spécificités essentielles
Produits associés
-
Quick ViewLire la suiteDisjoncteurs modulaires sur rail MCB: Acti9 IC60
A9F77416 – Disjoncteur 4P Courbe C Schneider Electric
-
Quick ViewAjouter au panier
-
Quick ViewAjouter au panier
Options et accessoires compatibles
Référence : XB4BS542
Marque : Schneider
Disponibilité : En Stock
- XB4BS542
- Characteristics
- Red Ø40 Emergency stop, switching off Ø22 latching
- turn release 1NC
- Main
- Range of product Harmony XB4
- Product or component type Complete emergency switching off push-button
- Device short name XB4
- Bezel material Chromium plated metal
- Fixing collar material Zamak
- Mounting diameter 22 mm
- Sale per indivisible quantity 1
- Shape of signaling unit head Round
- Type of operator Mechanical latching
- Reset Turn to release
- Operator profile Red mushroom Ø 40 mm unmarked
- Contacts type and composition 1 NC
- Contacts operation Slow-break
- Connections - terminals Screw clamp terminals : <= 2 x 1.5 mm² with cable
- end conforming to EN 60947-1
- Screw clamp terminals : >= 1 x 0.22 mm² without
- cable end conforming to EN 60947-1
- Complementary
- Height 47 mm
- Width 40 mm
- Depth 82 mm
- Terminals description ISO n°1 (21-22)NC
- Product weight 0.118 kg
- Resistance to high pressure washer 7000000 Pa at 55 °C,distance: 0.1 m
- Contacts usage Standard contacts
- Positive opening With positive opening conforming to EN/IEC 60947-5-1 appendix K
- Operating travel 1.5 mm (NC changing electrical state)
- 4.3 mm (total travel)
- Mechanical durability 300000 cycles
- Tightening torque 0.8...1.2 N.m conforming to EN 60947-1
- Shape of screw head Cross head compatible with Philips no 1 screwdriver
- Cross head compatible with pozidriv No 1 screwdriver
- Slotted head compatible with flat Ø 4 mm screwdriver
- Slotted head compatible with flat Ø 5.5 mm screwdriver
- Contacts material Silver alloy (Ag/Ni)
- Short circuit protection 10 A cartridge fuse type gG conforming to EN/IEC 60947-5-1
- [Ith] conventional free air thermal current 10 A conforming to EN/IEC 60947-5-1
- [Ui] rated insulation voltage 600 V (degree of pollution: 3) conforming to EN 60947-1
- [Uimp] rated impulse withstand voltage 6 kV conforming to EN 60947-1
- [Ie] rated operational current 3 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-1
- 6 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-1
- 0.1 A at 600 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
- 0.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
- 0.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
- 1.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-1
- Electrical durability 1000000 cycles, AC-15, 2 A at 230 V, operating rate: 3600 cyc/h, load factor: 0.5
- conforming to EN/IEC 60947-5-1 appendix C
- 1000000 cycles, AC-15, 3 A at 120 V, operating rate: 3600 cyc/h, load factor: 0.5
- conforming to EN/IEC 60947-5-1 appendix C
- 1000000 cycles, AC-15, 4 A at 24 V, operating rate: 3600 cyc/h, load factor: 0.5
- conforming to EN/IEC 60947-5-1 appendix C
- 1 / 3
- The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
- This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
- It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
- Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
- 1000000 cycles, DC-13, 0.2 A at 110 V, operating rate: 3600 cyc/h, load factor: 0.5
- conforming to EN/IEC 60947-5-1 appendix C
- 1000000 cycles, DC-13, 0.5 A at 24 V, operating rate: 3600 cyc/h, load factor: 0.5
- conforming to EN/IEC 60947-5-1 appendix C
- Electrical reliability IEC 60947-5-4 Λ < 10exp(-8) 17 V 5 mA in clean environment EN/IEC 60947-5-4
- Λ < 10exp(-6) 5 V 1 mA in clean environment EN/IEC 60947-5-4
- Environment
- protective treatment TH
- ambient air temperature for storage -40...70 °C
- ambient air temperature for operation -25...70 °C
- class of protection against electric shock Class I conforming to IEC 60536
- IP degree of protection IP66 conforming to IEC 60529
- NEMA degree of protection NEMA 13
- NEMA 4X
- IK degree of protection IK03 conforming to IEC 50102
- standards EN/IEC 60947-1
- EN/IEC 60947-5-1
- EN/IEC 60947-5-4
- EN/IEC 60947-5-5
- IEC 60364-5-53
- JIS C 4520
- UL 508
- CSA C22.2 No 14
- product certifications BV
- CSA
- DNV
- GL
- LROS (Lloyds register of shipping)
- RINA
- UL listed
- vibration resistance 5 gn (f = 2...500 Hz) conforming to IEC 60068-2-6
- shock resistance 30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-
- 27
- 50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-
- 27
- Contractual warranty
- Warranty period 18 months
- Dimensions
- e : clamping thickness: 1 to 6 mm / 0.04 to 0.24 in.
- Panel Cut-out for Pushbuttons, Switches and Pilot Lights (Finished Holes, Ready for Installation)
- Connection by Screw Clamp Terminals or Plug-in Connection by Faston Connectors
- Connectors or on Printed Circuit Board
- 2 / 3
- (1) Diameter on finished panel or support
- (2) 40 mm min. / 1.57 in. min.
- (3) 30 mm min. / 1.18 in. min.
- +0.4 +0.016
- (4) Ø 22.5 mm / 0.89 in. recommended (Ø 22.3 mm / 0.88 in. )
- 0 0
- (5) 45 mm min. / 1.78 in. min.
- (6) 32 mm min. / 1.26 in. min.
- 3 / 3