ABR1E118B
Characteristics
input interface module
17.5 mm - electromechanical
- 24 V AC/DC
1 NO
Main
Range of product Interface for discrete signals
Product or component type Electromechanical input interface module
Contacts type and composition 1 NO
[Uc] control circuit voltage 24 V
Control circuit type AC/DC
Control circuit frequency 50/60 Hz
Width pitch dimension 17.5 mm
[In] rated current <= 55 mA AC
<= 62 mA DC
Reverse polarity protection With
Short circuit protection 16 A external fuse gF (Ik <= 2.5 kA AC and Ik <=
100 A DC)
16 A external fuse gG (Ik <= 2.5 kA AC and Ik <=
100 A DC)
[Ith] conventional free air thermal 2 A conforming to IEC 60947
1
current
Local signalling Green mechanical indicator for position of
contacts and 1 green LED control signal state
Complementary
Control circuit voltage limits 30 V energization threshold
16.5 V
Housing colour Grey
Connections
terminals Screw clamp terminal
Drop
out voltage <= 3.8 V Holding current >= 4.9 mA DC
>= 5.2 mA AC
Power dissipation in W <= 1.5 W
Maximum switching voltage 125 V DC
252 V AC
[Ue] rated operational voltage <= 125 V DC conforming to IEC 60947
5-1
<= 230 V AC conforming to IEC 60947
5-1
Network frequency 50/60 Hz
[Ie] rated operational current 1 A AC
13 Ue: 230 V per 1000000 cycles conforming to IEC 60947-5-1
1 A AC
14 Ue: 230 V per 1000000 cycles conforming to IEC 60947-5-1
1 A AC
15 Ue: 230 V per 1000000 cycles conforming to IEC 60947-5-1
1 A DC
13 Ue: 24 V per 1000000 cycles conforming to IEC 60947-5-1
2 A AC
12 Ue: 230 V per 1000000 cycles conforming to IEC 60947-5-1
2 A DC
12 Ue: 24 V per 1000000 cycles conforming to IEC 60947-5-1
Minimum switching current 3 mA
Minimum switching voltage 17 V
Electrical reliability <= 0.00000001
Operating time <= 12 ms between de
energisation of coil and closing of NC contact
<= 12 ms between de
energisation of coil and closing of NO contact
<= 12 ms between energisation of coil and closing of NC contact
<= 12 ms between energisation of coil and closing of NO contact
Contact bounce time <= 3 ms
Operating rate in Hz <= 6 Hz at no
load
<= 0.5 Hz at Ie Mechanical durability >= 20000000 cycles
[Ui] rated insulation voltage 250 V conforming to IEC 60947
1
250 V conforming to VDE 0110 group C
Flame retardance V0 conforming to UL 94
Cable cross section 0.27...4 mm² , 1 wire rigid
1 / 3
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
0.34...2.5 mm² , 1 or 2 wires flexible with cable end
0.6...2.5 mm² , 1 or 2 wires flexible without cable end
0.27...2.5 mm² , 2 wires rigid
Operating position Any position
Installation category II conforming to IEC 60947
1
Mounting support Asymmetrical DIN rail
Combination rail
Symmetrical DIN rail
Product weight 0.095 kg
Environment
immunity to microbreaks 8 ms
dielectric strength 1500 V between independent contacts
2500 V between wired interface and earth
4000 V between coil circuit and contact circuits
standards IEC 60947
5-1
product certifications BV
CSA
DNV
LROS (Lloyds register of shipping)
UL
IP degree of protection IP20 conforming to IEC 60529
protective treatment TC
fire resistance 850 °C conforming to IEC 60695
2-1
shock resistance 50 gn for 11 ms conforming to IEC 60068
2-27
vibration resistance 6 gn (f = 10...55 Hz) conforming to IEC 60068
2-6
electromagnetic compatibility 1.2/50 ms shock waves immunity test, 0.25 kV for U > 50 V conforming to IEC 255
4
1.2/50 ms shock waves immunity test, 0.5 kV for U < 50 V conforming to IEC 255
4
Electrostatic discharge immunity test level 3, 8 kV conforming to IEC 61000
4-2
Rapid transients immunity test, on input/output 1 kV conforming to IEC 61000
4-4
Rapid transients immunity test, on power supply 2 kV conforming to IEC 61000
4-4
ambient air temperature for operation
20...60 °C at Un
-5...40 °C unrestricted operation
ambient air temperature for storage
40...70 °C
operating altitude <= 3000 m
pollution degree 3 conforming to IEC 60947
5-1
Contractual warranty
Warranty period 18 months
Electromechanical Interface Module
Dimensions
Electromechanical Interface Module
Example of Application with PLC
2 / 3
Interfacing PLC discrete inputs
S1, Pushbuttons series contacts
S2
(1) 2
wire sensors
(2) PLC positive logic discrete inputs
(3) 3
wire sensors
Interface with Mechanical Indication + LED
Circuit Diagram
1 N/O
3 / 3

Produits récemment consultés

Aucun produit récemment consulté à afficher
20 000

de références

Trouvez tout ce dont vous avez besoin dans notre catalogue.

Vaste choix
Livraison

adaptée à vos besoins

Solutions fiables et rapides pour votre quotidien.

Rapide & fiable
Experts

Des conseils personnalisés

Assistance technique de spécialistes pour vos projets.

Support dédié