substation - S84 - Sepam series 80Main

UGS : ee4189933f15

Spécificités essentielles

Produits associés

Options et accessoires compatibles

Référence :

59732 Marque : Schneider Disponibilité : En Stock



  • 59732
  • Characteristics
  • substation - S84 - Sepam series 80
  • Main
  • Relay application Substation
  • Range of product Sepam series 80
  • Sepam series 80 NPP
  • Device short name S84
  • Control and monitoring type Circuit breaker/contactor control ANSI code: 94/69 ( option )
  • Latching/Acknowledgement ANSI code: 86
  • Logic discrimination ANSI code: 68 ( option )
  • Switching of groups of settings
  • Annunciation ANSI code: 30
  • Automatic transfer (AT) ( option )
  • Logipam programming (ladder language) ( option )
  • Logic equation editor 200 operators
  • Metering type Measured residual current I0, calculated I'0∑
  • Positive sequence voltage Vd/rotation direction
  • Frequency
  • Calculated active and reactive energy (+/- W.h, +/- VAR.h)
  • Active and reactive energy by pulse counting (+/- W.h, +/- VAR.h) ( option )
  • Phase current I1, I2, I3 RMS
  • Demand current I1, I2, I3
  • Peak demand current IM1, IM2, IM3
  • Measured residual current I'0
  • Voltage U21, U32, U13, V1, V2, V3
  • Residual voltage V0
  • Negative sequence voltage Vi
  • Active power P, P1, P2, P3
  • Reactive power Q, Q1, Q2, Q3
  • Apparent power S, S1, S2, S3
  • Peak demand power PM, QM
  • Power factor
  • Network and machine diagnosis type Datalog (DLG)
  • Unbalance ratio/negative sequence current Ii
  • Disturbance recording
  • Thermal capacity used
  • Remaining operating time before overload tripping
  • Waiting time after overload tripping
  • Tripping context
  • Phase fault and earth fault trip counters
  • Harmonic distortion (THD), current and voltage Ithd, Uthd
  • Difference in amplitude, frequency and phase of voltages with synchro-check ( option )
  • Jun 12, 2017
  • 1
  • Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
  • Apparent positive sequence impedance Zd
  • Apparent phase-to-phase impedances Z21, Z32, Z13
  • Phase displacement
  • Switchgear diagnosis type CT/VT supervision ANSI code: 60FL
  • Trip circuit supervision ANSI code: 74 ( option )
  • Auxiliary power supply monitoring
  • Nb of operations, operating time, charging time, nb of racking out operations ( option )
  • Cumulative breaking current
  • Complementary
  • Type of measurement Peak demand power
  • Energy
  • Power (P,Q)
  • Voltage
  • Frequency
  • Power factor
  • Current
  • Protection type Directional active underpower  ANSI code:  37P
  • Rate of change of frequency  ANSI code:  81R
  • Directional earth fault ANSI code: 67N/67NC
  • Directional phase overcurrent ANSI code: 67
  • Synchro-check ( option ) ANSI code: 25
  • Overvoltage (L-L or L-N) ANSI code: 59
  • Thermal overload for cables ANSI code: 49RMS
  • Earth fault/sensitive earth fault ANSI code: 50N/51N
  • Earth fault/sensitive earth fault ANSI code: 50G/51G
  • Negative sequence/unbalance ANSI code: 46
  • Remanent undervoltage ANSI code: 27R
  • Overfrequency ANSI code: 81H
  • Underfrequency ANSI code: 81L
  • Negative sequence overvoltage ANSI code: 47
  • Directional active overpower ANSI code: 32P
  • Positive sequence undercurrent ANSI code: 27D
  • Undervoltage (L-L or L-N) ANSI code: 27
  • Breaker failure ANSI code: 50BF
  • Neutral voltage displacement ANSI code: 59N
  • Phase overcurrent ANSI code: 50/51
  • Recloser (4 cycles) ( option ) ANSI code: 79
  • Communication port protocol Measurement readout ( option ) : Modbus
  • Remote control orders ( option ) : Modbus
  • Remote indication and time tagging of events ( option ) : Modbus
  • Remote protection setting ( option ) : Modbus
  • Transfer of disturbance recording data ( option ) : Modbus
  • Input output max capacity 42 inputs + 23 outputs
  • Communication compatibility Modbus RTU
  • DNP3
  • IEC 61850
  • IEC 60870-5-103
  • IEC 61850 goose message
  • Modbus TCPIP
  • User machine interface type Advanced
  • Remote
  • Without
  • Mimic-based
  • 2

Produits Similaires

100 000 de références

Trouvez tout ce dont vous avez besoin dans notre catalogue

Livraison adaptée à vos besoins

Nos solutions de livraison fiables et rapides facilitent votre quotidien

Des conseils d’expert

Recevez une assistance technique de spécialistes pour soutenir vos projets

4
    4
    Votre panier
    EZC100H1016
    EZC100H1016
    1 X 5.319,71DZD = 5.319,71DZD
    NSYEC126
    NSYEC126
    1 X 12.359,12DZD = 12.359,12DZD
    XS7D1A1PBL5
    XS7D1A1PBL5
    1 X 11.984,19DZD = 11.984,19DZD
    PKY32G725
    PKY32G725
    1 X 5.248,75DZD = 5.248,75DZD