Nos marques

Tous les produits Schneider

Produits récemment consultés

EPH3500221

1.236,83DZD

A9C20531

3.623,90DZD

K10F013NCH

8.112,61DZD

LE1M35B721

14.131,47DZD

A9F75602

ACTI9 IC60N 1P-N 2A D DISJONCTEUR MINIAT

6.001,47DZD

UGS : 70cb399a62c6

Spécificités essentielles

Produits associés

Options et accessoires compatibles

Description du pruit
Référence :

A9F75602 Marque : Schneider Disponibilité : En Stock



  • A9F75602
  • Characteristics
  • iC60N - miniature circuit breaker - 1P + N - 2A - D
  • curve
  • Main
  • Device application Distribution
  • Range Acti 9
  • Product name Acti 9 iC60
  • Product or component type Miniature circuit-breaker
  • Device short name IC60N
  • Poles description 1P + N
  • Number of protected poles 1
  • Neutral position Left
  • [In] rated current 2 A
  • Network type AC
  • Trip unit technology Thermal-magnetic
  • Curve code D
  • Breaking capacity 50 kA Icu conforming to IEC 60947-2 - 100...133 V AC 50/60 Hz
  • 50 kA Icu conforming to EN 60947-2 - 100...133 V AC 50/60 Hz
  • 50 kA Icu conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz
  • 6000 A Icn conforming to EN 60898-1 - 230 V AC 50/60 Hz
  • 50 kA Icu conforming to EN 60947-2 - 12...60 V AC 50/60 Hz
  • 50 kA Icu conforming to EN 60947-2 - 220...240 V AC 50/60 Hz
  • 50 kA Icu conforming to IEC 60947-2 - 12...60 V AC 50/60 Hz
  • 6000 A Icn conforming to IEC 60898-1 - 230 V AC 50/60 Hz
  • Utilisation category Category A conforming to EN 60947-2
  • Category A conforming to IEC 60947-2
  • Suitability for isolation Yes conforming to EN 60947-2
  • Yes conforming to IEC 60947-2
  • Yes conforming to EN 60898-1
  • Yes conforming to IEC 60898-1
  • Standards EN 60898-1
  • EN 60947-2
  • IEC 60898-1
  • IEC 60947-2
  • Jun 12, 2017
  • 1
  • Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
  • Complementary
  • Network frequency 50/60 Hz
  • Magnetic tripping limit 12 x In +/- 20 %
  • [Ics] rated service breaking capacity 6000 A 100 % x Icu conforming to IEC 60898-1 - 230 V AC 50/60 Hz
  • 6000 A 100 % x Icu conforming to EN 60898-1 - 230 V AC 50/60 Hz
  • 50 kA 100 % x Icu conforming to EN 60947-2 - 12...60 V AC 50/60 Hz
  • 50 kA 100 % x Icu conforming to EN 60947-2 - 220...240 V AC 50/60 Hz
  • 50 kA 100 % x Icu conforming to IEC 60947-2 - 12...60 V AC 50/60 Hz
  • 50 kA 100 % x Icu conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz
  • 50 kA 100 % x Icu conforming to IEC 60947-2 - 100...133 V AC 50/60 Hz
  • 50 kA 100 % x Icu conforming to EN 60947-2 - 100...133 V AC 50/60 Hz
  • [Ui] rated insulation voltage 500 V AC 50/60 Hz conforming to IEC 60947-2
  • 500 V AC 50/60 Hz conforming to EN 60947-2
  • [Uimp] rated impulse withstand voltage 6 kV conforming to EN 60947-2
  • 6 kV conforming to IEC 60947-2
  • Contact position indicator Yes
  • Control type Toggle
  • Local signalling Trip indicator
  • Mounting mode Fixed
  • Mounting support DIN rail
  • Comb busbar distribution block YES top or bottom
  • compatibility
  • 9 mm pitches 4
  • Height 85 mm
  • Width 36 mm
  • Depth 78.5 mm
  • Product weight 0.25 kg
  • Colour White
  • Mechanical durability 20000 cycles
  • Electrical durability 10000 cycles
  • Connections - terminals Single terminal, top or bottom rigid wire(s) 1...25 mm² max
  • Single terminal, top or bottom flexible wire(s) 1...16 mm² max
  • Wire stripping length 14 mm top or bottom
  • Tightening torque 2 N.m top or bottom
  • Earth-leakage protection Separate block
  • Environment
  • IP degree of protection IP20 conforming to EN 60529
  • IP20 conforming to IEC 60529
  • Pollution degree 3 conforming to EN 60947-2
  • 3 conforming to IEC 60947-2
  • Overvoltage category IV
  • Tropicalisation 2 conforming to IEC 60068-1
  • Relative humidity 95 % ( 55 °C )
  • Operating altitude 0...2000 m
  • Ambient air temperature for operation -35...70 °C
  • Ambient air temperature for storage -40...85 °C
  • Offer Sustainability
  • Sustainable offer status Green Premium product
  • RoHS (date code: YYWW) Compliant  - since  1001  -  Schneider Electric declaration of conformity
  • Schneider Electric declaration of conformity
  • REACh Reference not containing SVHC above the threshold
  • Reference not containing SVHC above the threshold
  • 2
  • Product environmental profile Available
  • Product end of life instructions Need no specific recycling operations
  • 3

Produits Similaires

100 000 de références

Trouvez tout ce dont vous avez besoin dans notre catalogue

Livraison adaptée à vos besoins

Nos solutions de livraison fiables et rapides facilitent votre quotidien

Des conseils d’expert

Recevez une assistance technique de spécialistes pour soutenir vos projets

15
    15
    Votre panier
    ZC4GM9
    ZC4GM9
    1 X 159.329,68DZD = 159.329,68DZD
    13136
    13136
    1 X 584,58DZD = 584,58DZD
    ATV320U15M2C
    ATV320U15M2C
    1 X 66.284,80DZD = 66.284,80DZD
    ALB45226
    ALB45226
    1 X 2.232,71DZD = 2.232,71DZD
    PRA90072
    PRA90072
    1 X 15.452,22DZD = 15.452,22DZD
    VLVAW0L007A40B
    VLVAW0L007A40B
    1 X 262.236,21DZD = 262.236,21DZD
    schneider
    ZC4GM8
    1 X 149.050,35DZD = 149.050,35DZD
    LX1D6N6
    LX1D6N6
    1 X 3.834,66DZD = 3.834,66DZD
    EPH3500121
    EPH3500121
    1 X 1.236,83DZD = 1.236,83DZD
    12912
    12912
    1 X 520,12DZD = 520,12DZD
    LE1M35B721
    LE1M35B721
    1 X 14.131,47DZD = 14.131,47DZD
    9001KP35LYA9
    9001KP35LYA9
    1 X 5.906,73DZD = 5.906,73DZD
    XS7E1A1CAL08M12
    XS7E1A1CAL08M12
    1 X 10.824,26DZD = 10.824,26DZD
    MGU3.211.18
    MGU3.211.18
    1 X 743,37DZD = 743,37DZD
    18621
    18621
    1 X 18.893,31DZD = 18.893,31DZD