Nos marques

Tous les produits Schneider

Produits récemment consultés

KBC16DCB226

3.943,95DZD

LADC223

8.066,84DZD

PKF32M415

2.934,64DZD

A9F73604

4.750,15DZD

A9F83425

ACTI9 IC60H 4P 25A B DISJONCTEUR MINIATU

11.744,58DZD

UGS : c9ed908b5dfb

Spécificités essentielles

Produits associés

Options et accessoires compatibles

Référence :

A9F83425 Marque : Schneider Disponibilité : En Stock



  • A9F83425
  • Characteristics
  • iC60H - miniature circuit breaker - 4P - 25A - B
  • curve
  • Main
  • Device application Distribution
  • Range Acti 9
  • Product name Acti 9 iC60
  • Product or component type Miniature circuit-breaker
  • Device short name IC60H
  • Poles description 4P
  • Number of protected poles 4
  • [In] rated current 25 A
  • Network type AC
  • DC
  • Trip unit technology Thermal-magnetic
  • Curve code B
  • Breaking capacity 42 kA Icu conforming to IEC 60947-2 - 12...133 V AC 50/60 Hz
  • 42 kA Icu conforming to EN 60947-2 - 12...133 V AC 50/60 Hz
  • 15 kA Icu conforming to EN 60947-2 - 180...250 V DC
  • 15 kA Icu conforming to IEC 60947-2 - 180...250 V DC
  • 10 kA Icu conforming to IEC 60947-2 - 440 V AC 50/60 Hz
  • 10 kA Icu conforming to EN 60947-2 - 440 V AC 50/60 Hz
  • 10000 A Icn conforming to EN 60898-1 - 400 V AC 50/60 Hz
  • 10000 A Icn conforming to IEC 60898-1 - 400 V AC 50/60 Hz
  • 15 kA Icu conforming to EN 60947-2 - 380...415 V AC 50/60 Hz
  • 15 kA Icu conforming to IEC 60947-2 - 380...415 V AC 50/60 Hz
  • 30 kA Icu conforming to EN 60947-2 - 220...240 V AC 50/60 Hz
  • 30 kA Icu conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz
  • Utilisation category Category A conforming to EN 60947-2
  • Category A conforming to IEC 60947-2
  • Suitability for isolation Yes conforming to EN 60947-2
  • Yes conforming to IEC 60947-2
  • Yes conforming to EN 60898-1
  • Yes conforming to IEC 60898-1
  • Standards EN 60898-1
  • EN 60947-2
  • IEC 60898-1
  • Jun 12, 2017
  • 1
  • Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
  • IEC 60947-2
  • Complementary
  • Network frequency 50/60 Hz
  • Magnetic tripping limit 4 x In +/- 20 %
  • [Ics] rated service breaking capacity 7500 A 75 % x Icu conforming to EN 60898-1 - 400 V AC 50/60 Hz
  • 7500 A 75 % x Icu conforming to IEC 60898-1 - 400 V AC 50/60 Hz
  • 21 kA 50 % x Icu conforming to IEC 60947-2 - 12...133 V AC 50/60 Hz
  • 21 kA 50 % x Icu conforming to EN 60947-2 - 12...133 V AC 50/60 Hz
  • 15 kA 100 % x Icu conforming to IEC 60947-2 - 180...250 V DC
  • 15 kA 100 % x Icu conforming to EN 60947-2 - 180...250 V DC
  • 5 kA 50 % x Icu conforming to IEC 60947-2 - 440 V AC 50/60 Hz
  • 15 kA 50 % x Icu conforming to EN 60947-2 - 220...240 V AC 50/60 Hz
  • 7.5 kA 50 % x Icu conforming to EN 60947-2 - 380...415 V AC 50/60 Hz
  • 5 kA 50 % x Icu conforming to EN 60947-2 - 440 V AC 50/60 Hz
  • 15 kA 50 % x Icu conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz
  • 7.5 kA 50 % x Icu conforming to IEC 60947-2 - 380...415 V AC 50/60 Hz
  • Limitation class 3 conforming to EN 60898-1
  • 3 conforming to IEC 60898-1
  • [Ui] rated insulation voltage 500 V AC 50/60 Hz conforming to IEC 60947-2
  • 500 V AC 50/60 Hz conforming to EN 60947-2
  • [Uimp] rated impulse withstand voltage 6 kV conforming to EN 60947-2
  • 6 kV conforming to IEC 60947-2
  • Contact position indicator Yes
  • Control type Toggle
  • Local signalling Trip indicator
  • Mounting mode Fixed
  • Mounting support DIN rail
  • Comb busbar distribution block YES top or bottom
  • compatibility
  • 9 mm pitches 8
  • Height 85 mm
  • Width 72 mm
  • Depth 78.5 mm
  • Product weight 0.5 kg
  • Colour White
  • Mechanical durability 20000 cycles
  • Electrical durability 10000 cycles
  • Connections - terminals Single terminal, top or bottom rigid wire(s) 1...25 mm² max
  • Single terminal, top or bottom flexible wire(s) 1...16 mm² max
  • Wire stripping length 14 mm top or bottom
  • Tightening torque 2 N.m top or bottom
  • Earth-leakage protection Separate block
  • Environment
  • IP degree of protection IP20 conforming to EN 60529
  • IP20 conforming to IEC 60529
  • Pollution degree 3 conforming to EN 60947-2
  • 3 conforming to IEC 60947-2
  • Overvoltage category IV
  • Tropicalisation 2 conforming to IEC 60068-1
  • Relative humidity 95 % ( 55 °C )
  • Operating altitude 0...2000 m
  • Ambient air temperature for operation -35...70 °C
  • Ambient air temperature for storage -40...85 °C
  • 2
  • Offer Sustainability
  • Sustainable offer status Green Premium product
  • RoHS (date code: YYWW) Compliant  - since  1001  -  Schneider Electric declaration of conformity
  • Schneider Electric declaration of conformity
  • REACh Reference not containing SVHC above the threshold
  • Reference not containing SVHC above the threshold
  • Product environmental profile Available
  • Product end of life instructions Need no specific recycling operations
  • 3

Produits Similaires

100 000 de références

Trouvez tout ce dont vous avez besoin dans notre catalogue

Livraison adaptée à vos besoins

Nos solutions de livraison fiables et rapides facilitent votre quotidien

Des conseils d’expert

Recevez une assistance technique de spécialistes pour soutenir vos projets

10
    10
    Votre panier
    13143
    13143
    1 X 1.070,14DZD = 1.070,14DZD
    MVS16N3MW6V
    MVS16N3MW6V
    1 X 759.462,72DZD = 759.462,72DZD
    CA2KN22U7
    CA2KN22U7
    2 X 3.788,71DZD = 7.577,42DZD
    16905
    16905
    1 X 76.379,65DZD = 76.379,65DZD
    KSA630DLC4A
    KSA630DLC4A
    1 X 284.684,70DZD = 284.684,70DZD
    KSA630DLC40
    KSA630DLC40
    1 X 197.355,78DZD = 197.355,78DZD
    ZB4BW0G45
    ZB4BW0G45
    1 X 2.074,10DZD = 2.074,10DZD
    MVS40N3MW6L
    MVS40N3MW6L
    1 X 1.775.865,41DZD = 1.775.865,41DZD
    12911
    12911
    1 X 519,75DZD = 519,75DZD