Fiche technique du produit PDF : 

UGS : 5e6b2c7fd0ab Catégorie :
INTERF R EM E1F 24V LED

9.338,39DZD

UGS : 5e6b2c7fd0ab
Produits associés
Référence :

ABR1E118B Marque : Schneider Disponibilité : En Stock



  • ABR1E118B
  • Characteristics
  • input interface module - 17.5 mm - electromechanical
  • - 24 V AC/DC - 1 NO
  • Main
  • Range of product Interface for discrete signals
  • Product or component type Electromechanical input interface module
  • Contacts type and composition 1 NO
  • [Uc] control circuit voltage 24 V
  • Control circuit type AC/DC
  • Control circuit frequency 50/60 Hz
  • Width pitch dimension 17.5 mm
  • [In] rated current <= 55 mA AC
  • <= 62 mA DC
  • Reverse polarity protection With
  • Short circuit protection 16 A external fuse gF (Ik <= 2.5 kA AC and Ik <=
  • 100 A DC)
  • 16 A external fuse gG (Ik <= 2.5 kA AC and Ik <=
  • 100 A DC)
  • [Ith] conventional free air thermal 2 A conforming to IEC 60947-1
  • current
  • Local signalling Green mechanical indicator for position of
  • contacts and 1 green LED control signal state
  • Complementary
  • Control circuit voltage limits 30 V energization threshold: 16.5 V
  • Housing colour Grey
  • Connections - terminals Screw clamp terminal
  • Drop-out voltage <= 3.8 V Holding current >= 4.9 mA DC
  • >= 5.2 mA AC
  • Power dissipation in W <= 1.5 W
  • Maximum switching voltage 125 V DC
  • 252 V AC
  • [Ue] rated operational voltage <= 125 V DC conforming to IEC 60947-5-1
  • <= 230 V AC conforming to IEC 60947-5-1
  • Network frequency 50/60 Hz
  • [Ie] rated operational current 1 A AC-13 Ue: 230 V per 1000000 cycles conforming to IEC 60947-5-1
  • 1 A AC-14 Ue: 230 V per 1000000 cycles conforming to IEC 60947-5-1
  • 1 A AC-15 Ue: 230 V per 1000000 cycles conforming to IEC 60947-5-1
  • 1 A DC-13 Ue: 24 V per 1000000 cycles conforming to IEC 60947-5-1
  • 2 A AC-12 Ue: 230 V per 1000000 cycles conforming to IEC 60947-5-1
  • 2 A DC-12 Ue: 24 V per 1000000 cycles conforming to IEC 60947-5-1
  • Minimum switching current 3 mA
  • Minimum switching voltage 17 V
  • Electrical reliability <= 0.00000001
  • Operating time <= 12 ms between de-energisation of coil and closing of NC contact
  • <= 12 ms between de-energisation of coil and closing of NO contact
  • <= 12 ms between energisation of coil and closing of NC contact
  • <= 12 ms between energisation of coil and closing of NO contact
  • Contact bounce time <= 3 ms
  • Operating rate in Hz <= 6 Hz at no-load
  • <= 0.5 Hz at Ie Mechanical durability >= 20000000 cycles
  • [Ui] rated insulation voltage 250 V conforming to IEC 60947-1
  • 250 V conforming to VDE 0110 group C
  • Flame retardance V0 conforming to UL 94
  • Cable cross section 0.27...4 mm² , 1 wire rigid
  • 1 / 3
  • The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
  • This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
  • It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
  • Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
  • 0.34...2.5 mm² , 1 or 2 wires flexible with cable end
  • 0.6...2.5 mm² , 1 or 2 wires flexible without cable end
  • 0.27...2.5 mm² , 2 wires rigid
  • Operating position Any position
  • Installation category II conforming to IEC 60947-1
  • Mounting support Asymmetrical DIN rail
  • Combination rail
  • Symmetrical DIN rail
  • Product weight 0.095 kg
  • Environment
  • immunity to microbreaks 8 ms
  • dielectric strength 1500 V between independent contacts
  • 2500 V between wired interface and earth
  • 4000 V between coil circuit and contact circuits
  • standards IEC 60947-5-1
  • product certifications BV
  • CSA
  • DNV
  • LROS (Lloyds register of shipping)
  • UL
  • IP degree of protection IP20 conforming to IEC 60529
  • protective treatment TC
  • fire resistance 850 °C conforming to IEC 60695-2-1
  • shock resistance 50 gn for 11 ms conforming to IEC 60068-2-27
  • vibration resistance 6 gn (f = 10...55 Hz) conforming to IEC 60068-2-6
  • electromagnetic compatibility 1.2/50 ms shock waves immunity test, 0.25 kV for U > 50 V conforming to IEC 255-4
  • 1.2/50 ms shock waves immunity test, 0.5 kV for U < 50 V conforming to IEC 255-4
  • Electrostatic discharge immunity test level 3, 8 kV conforming to IEC 61000-4-2
  • Rapid transients immunity test, on input/output 1 kV conforming to IEC 61000-4-4
  • Rapid transients immunity test, on power supply 2 kV conforming to IEC 61000-4-4
  • ambient air temperature for operation -20...60 °C at Un
  • -5...40 °C unrestricted operation
  • ambient air temperature for storage -40...70 °C
  • operating altitude <= 3000 m
  • pollution degree 3 conforming to IEC 60947-5-1
  • Contractual warranty
  • Warranty period 18 months
  • Electromechanical Interface Module
  • Dimensions
  • Electromechanical Interface Module
  • Example of Application with PLC
  • 2 / 3
  • Interfacing PLC discrete inputs
  • S1, Pushbuttons series contacts
  • S2
  • (1) 2-wire sensors
  • (2) PLC positive logic discrete inputs
  • (3) 3-wire sensors
  • Interface with Mechanical Indication + LED
  • Circuit Diagram
  • 1 N/O
  • 3 / 3

Produits qui pourraient aussi répondre à vos besoins

Produits récemment consultés

Aucun produit récemment consulté à afficher
références de produits

100 000 de références

Trouvez tout ce dont vous avez besoin dans notre catalogue

livraison rapide

Livraison adaptée à vos besoins

Nos solutions de livraison fiables et rapides facilitent votre quotidien

expert senia electrique

Des conseils d’expert

Recevez une assistance technique de spécialistes pour soutenir vos projets

Panier
Retour en haut