EZC100B3040
UGS : 80ce2d9fcf04
Catégorie : Disjoncteurs forte puissance (boitier moulé et ouvert)
MG EZC100B 7.5kA 3P/3T 40A
8.568,02DZD
UGS :
80ce2d9fcf04
Spécificités essentielles
Ce produit n’est pas celui que vous recherchez ? Cliquez ici pour voir les produits de la catégorie :
Produits associés
- Quick ViewAjouter au panier
TRV00917
58.540,65DZD - Quick ViewAjouter au panier
TRV00880
5.930,02DZD - Quick ViewAjouter au panier
TRV00870
9.386,85DZD
Produits liés à cet article
Référence : EZC100B3040
Marque : Schneider
Disponibilité : En Stock
- EZC100B3040
- Characteristics
- circuit breaker Easypact EZC100B - TMD - 40 A -
- 3 poles 3d
- Main
- Range of product EasyPact
- Product or component type Circuit breaker
- Device short name Easypact EZC100B
- Circuit breaker name Easypact EZC100B
- Device application Distribution
- Poles description 3P
- Protected poles description 3t
- Network type AC
- DC
- Network frequency 50/60 Hz
- [In] rated current 100 A ( 40 °C )
- [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
- [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2
- [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2
- Breaking capacity code B
- Breaking capacity 10 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2
- 10 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
- 5 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
- 2.5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2
- 7.5 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2
- 7.5 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2
- [Ics] rated service breaking capacity Ics 0.625 kA 550 V AC 50/60 Hz conforming to IEC 60947-2
- Ics 1.25 kA 440 V AC 50/60 Hz conforming to IEC 60947-2
- Ics 1.875 kA 380 V AC 50/60 Hz conforming to IEC 60947-2
- Ics 1.875 kA 400/415 V AC 50/60 Hz conforming to IEC 60947-2
- Ics 2.5 kA 110/130 V AC 50/60 Hz conforming to IEC 60947-2
- Ics 2.5 kA 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2
- Suitability for isolation Yes conforming to IEC 60947-2
- Utilisation category Category A
- Trip unit name TM-D
- Trip unit technology Thermal-magnetic
- Jun 12, 2017
- 1
- Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
- Trip unit rating 40 A ( 50 °C )
- Protection type Overload protection
- Short-circuit protection
- Pollution degree 3 conforming to IEC 60664-1
- 3 conforming to IEC 947-1
- Complementary
- Control type Toggle
- Mounting mode Fixed
- Mounting support Backplate
- Upside connection Front
- Downside connection Front
- Mechanical durability 8500 cycles
- Electrical durability Category A : 1500 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2
- Connection pitch 25 mm
- Local signalling Positive contact indication
- Neutral protection setting Without protection
- Earth-leakage protection Without
- Height 130 mm
- Width 75 mm
- Depth 60 mm
- Environment
- Standards GB 14048.2
- IEC 60947-2
- JIS C8201-2-2
- NEMA AB1
- IP degree of protection IP20 conforming to IEC 60529
- IK degree of protection IK07 conforming to IEC 62262
- Ambient air temperature for operation -25...70 °C
- Ambient air temperature for storage -35...85 °C
- Contractual warranty
- Warranty period 18 months
- 2
Produits Similaires
Produits similaires
Produits récemment consultés
Aucun produit récemment consulté à afficher