Nos marques

Tous les produits Schneider

Produits récemment consultés

MGU3.106.25

351,65DZD

LU2B32ES

65.930,31DZD

VLVB195

1.903.006,62DZD

XB5AV5B4

5.038,12DZD

MVS40N3MW5L

UGS : 84aa2ead97b3 Catégorie :
EP MVS CB 4000A 55kA 3P MDO ET5 drawout

1.741.044,51DZD

UGS : 84aa2ead97b3

Spécificités essentielles

Produits associés

Options et accessoires compatibles

Description du pruit
Référence :

MVS40N3MW5L Marque : Schneider Disponibilité : En Stock



  • MVS40N3MW5L
  • Characteristics
  • EP MVS CB 4000A 55kA 3P MDO ET5 drawout
  • manual Circuit breaker
  • Main
  • Range of product EasyPact MVS
  • Range EasyPact
  • Product name MVS40N
  • Device short name MVS40N
  • Product or component type Circuit breaker
  • Device application Distribution
  • Poles description 3P
  • Protected poles description 3P 3d
  • Network type AC
  • Breaking capacity code N
  • Suitability for isolation Yes conforming to IEC 60947-2
  • Utilisation category Category B
  • Trip unit name ET5S
  • Trip unit technology Electronic
  • Trip unit rating 4000 A (-5...70 °C)
  • Complementary
  • Network frequency 50/60 Hz
  • Control type Manually operated
  • Mounting mode Drawout
  • Mounting support Base plate
  • Rail
  • Connection position Horizontal
  • Vertical
  • Location of connection Rear
  • [In] rated current 4000 A (40 °C)
  • [Ui] rated insulation voltage 1000 V AC 50/60 Hz conforming to IEC 60947-2
  • [Uimp] rated impulse withstand voltage 12 kV conforming to IEC 60947-2
  • Jun 12, 2017
  • 1
  • Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
  • [Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
  • Circuit breaker CT rating 4000 A
  • Breaking capacity 55 kA (Icu) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
  • [Ics] rated service breaking capacity 55 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
  • Mechanical durability 20000 cycles (with maintenance) conforming to IEC 60947-2
  • 10000 cycles (without maintenance) conforming to IEC 60947-2
  • Electrical durability 5000 cycles (without maintenance), category B at 440 V AC 50/60 Hz, conforming to IEC 60947-2
  • 2500 cycles (without maintenance), category B at 690 V AC 50/60 Hz, conforming to IEC 60947-2
  • Connection pitch 115 mm (without spreader)
  • Contact position indicator Yes
  • [Icm] rated short-circuit making 121 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
  • capacity
  • [Icw] rated short-time withstand current 42 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2
  • 55 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
  • 30 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2
  • Trip unit protection functions LSI
  • Protection type Instantaneous short-circuit protection
  • Overload protection (long time)
  • Short time short-circuit protection
  • Fault indication Overload
  • Short-circuit
  • Internal fault
  • Long time pick-up adjstment type Ir Adjustable 9 settings
  • Long time pick-up adjustment range 0.4...1 x In
  • Long time delay adjustment type Adjustable 9 settings
  • [Tr] long-time delay adjustment 0.5...24 s (6 x Ir)
  • Short-time pick-up adjustment type Isd Adjustable 9 settings
  • [Isd] short-time pick-up adjustment 1.5...10 x Ir
  • range
  • Short-time delay adjustment type Adjustable 5 settings
  • [Tsd] short-time delay adjustment 100...400 ms
  • range
  • Instantaneous pick-up adjustment type Adjustable 9 settings
  • Ii
  • Instantaneous pick-up adjustment 2...15 x In
  • range Off
  • Zone selective interlocking ZSI With
  • Current sensor rating range 1000/4000 A
  • Maximum breaking time 25 ms
  • Closing response time < 70 ms
  • Height 439 mm
  • Width 441 mm
  • Depth 395 mm
  • Product weight 90 kg
  • Environment
  • Standards IEC 60947-2
  • Product certifications CCC
  • GOST
  • IEC
  • CCS
  • IP degree of protection IP40
  • Pollution degree 4 conforming to IEC 60664-1
  • Ambient air temperature for operation -5...70 °C
  • Ambient air temperature for storage -40...85 °C (without control unit)
  • -25...85 °C (with control unit)
  • 2
  • Offer Sustainability
  • Sustainable offer status Green Premium product
  • RoHS (date code: YYWW) Compliant  - since  1440  -  Schneider Electric declaration of conformity
  • Schneider Electric declaration of conformity
  • REACh Reference not containing SVHC above the threshold
  • Reference not containing SVHC above the threshold
  • Product environmental profile Available
  • Product environmental
  • Product end of life instructions Available
  • End of life manual
  • Contractual warranty
  • Warranty period 18 months
  • 3

Produits Similaires

100 000 de références

Trouvez tout ce dont vous avez besoin dans notre catalogue

Livraison adaptée à vos besoins

Nos solutions de livraison fiables et rapides facilitent votre quotidien

Des conseils d’expert

Recevez une assistance technique de spécialistes pour soutenir vos projets

11
    11
    Votre panier
    GS2V4
    GS2V4
    1 X 585.062,78DZD = 585.062,78DZD
    MVS40N3MW5L
    MVS40N3MW5L
    1 X 1.741.044,51DZD = 1.741.044,51DZD
    ALB44212
    ALB44212
    1 X 829,30DZD = 829,30DZD
    NSYSF14640
    NSYSF14640
    1 X 134.260,88DZD = 134.260,88DZD
    9001KP35LWW9
    9001KP35LWW9
    1 X 5.465,67DZD = 5.465,67DZD
    NSYSFD208
    NSYSFD208
    1 X 50.098,95DZD = 50.098,95DZD
    NSYPMM105
    NSYPMM105
    1 X 6.035,12DZD = 6.035,12DZD
    NSYMPC206
    NSYMPC206
    1 X 5.000,96DZD = 5.000,96DZD
    LS1D303
    LS1D303
    1 X 8.558,65DZD = 8.558,65DZD
    LA6DK20Q
    LA6DK20Q
    1 X 9.266,42DZD = 9.266,42DZD
    K1C007BL