Nos marques

Tous les produits Schneider

Produits récemment consultés

A9F73604

4.750,15DZD

XPER110EX

24.841,66DZD

XALG05

4.354,71DZD

MVS40N3MW6L

UGS : edd746ba402c Catégorie :
EP MVS CB 4000A 55kA 3P MDO ET6 drawout

1.775.865,41DZD

UGS : edd746ba402c

Spécificités essentielles

Produits associés

Options et accessoires compatibles

Référence :

MVS40N3MW6L Marque : Schneider Disponibilité : En Stock



  • MVS40N3MW6L
  • Characteristics
  • EP MVS CB 4000A 55kA 3P MDO ET6 drawout
  • manual Circuit breaker
  • Main
  • Range of product EasyPact MVS
  • Range EasyPact
  • Product name MVS40N
  • Device short name MVS40N
  • Product or component type Circuit breaker
  • Device application Distribution
  • Poles description 3P
  • Protected poles description 3P 3d
  • Network type AC
  • Breaking capacity code N
  • Suitability for isolation Yes conforming to IEC 60947-2
  • Utilisation category Category B
  • Trip unit name ET6G
  • Trip unit technology Electronic
  • Trip unit rating 4000 A (-5...70 °C)
  • Complementary
  • Network frequency 50/60 Hz
  • Control type Manually operated
  • Mounting mode Drawout
  • Mounting support Base plate
  • Rail
  • Connection position Horizontal
  • Vertical
  • Location of connection Rear
  • [In] rated current 4000 A (40 °C)
  • [Ui] rated insulation voltage 1000 V AC 50/60 Hz conforming to IEC 60947-2
  • [Uimp] rated impulse withstand voltage 12 kV conforming to IEC 60947-2
  • Jun 12, 2017
  • 1
  • Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
  • [Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
  • Circuit breaker CT rating 4000 A
  • Breaking capacity 55 kA (Icu) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
  • [Ics] rated service breaking capacity 55 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
  • Mechanical durability 20000 cycles (with maintenance) conforming to IEC 60947-2
  • 10000 cycles (without maintenance) conforming to IEC 60947-2
  • Electrical durability 5000 cycles (without maintenance), category B at 440 V AC 50/60 Hz, conforming to IEC 60947-2
  • 2500 cycles (without maintenance), category B at 690 V AC 50/60 Hz, conforming to IEC 60947-2
  • Connection pitch 115 mm (without spreader)
  • Contact position indicator Yes
  • [Icm] rated short-circuit making 121 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
  • capacity
  • [Icw] rated short-time withstand current 42 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2
  • 55 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
  • 30 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2
  • Trip unit protection functions LSIG
  • Protection type Earth fault
  • Instantaneous short-circuit protection
  • Overload protection (long time)
  • Short time short-circuit protection
  • Fault indication Overload
  • Short-circuit
  • Internal fault
  • Earth fault
  • Long time pick-up adjstment type Ir Adjustable 9 settings
  • Long time pick-up adjustment range 0.4...1 x In
  • Long time delay adjustment type Adjustable 9 settings
  • [Tr] long-time delay adjustment 0.5...24 s (6 x Ir)
  • Short-time pick-up adjustment type Isd Adjustable 9 settings
  • [Isd] short-time pick-up adjustment 1.5...10 x Ir
  • range
  • Short-time delay adjustment type Adjustable 5 settings
  • [Tsd] short-time delay adjustment 100...400 ms
  • range
  • Instantaneous pick-up adjustment type Adjustable 9 settings
  • Ii
  • Instantaneous pick-up adjustment 2...15 x In
  • range Off
  • Ground-fault pick-up adjustment type Adjustable 9 settings
  • Ground-fault time delay adjustment Adjustable 5 settings
  • type -tg
  • [Tg] ground-fault time delay 100...400 ms
  • adjustment range
  • [Ig] ground-fault pick-up adjustment 500...1200 A
  • range
  • Zone selective interlocking ZSI With
  • Current sensor rating range 1000/4000 A
  • Maximum breaking time 25 ms
  • Closing response time < 70 ms
  • Height 439 mm
  • Width 441 mm
  • Depth 395 mm
  • Product weight 90 kg
  • Environment
  • Standards IEC 60947-2
  • Product certifications CCC
  • GOST
  • IEC
  • 2
  • CCS
  • IP degree of protection IP40
  • Pollution degree 4 conforming to IEC 60664-1
  • Ambient air temperature for operation -5...70 °C
  • Ambient air temperature for storage -40...85 °C (without control unit)
  • -25...85 °C (with control unit)
  • Offer Sustainability
  • Sustainable offer status Not Green Premium product
  • RoHS (date code: YYWW) Will be compliant  on  2Q2016
  • Will be compliant  on  2Q2016
  • REACh Reference not containing SVHC above the threshold
  • Reference not containing SVHC above the threshold
  • Product environmental profile Available
  • Product environmental
  • Product end of life instructions Available
  • End of life manual
  • Contractual warranty
  • Warranty period 18 months
  • 3

Produits Similaires

100 000 de références

Trouvez tout ce dont vous avez besoin dans notre catalogue

Livraison adaptée à vos besoins

Nos solutions de livraison fiables et rapides facilitent votre quotidien

Des conseils d’expert

Recevez une assistance technique de spécialistes pour soutenir vos projets

10
    10
    Votre panier
    ATS48C14Y
    ATS48C14Y
    1 X 341.179,74DZD = 341.179,74DZD
    ABE7H16R20
    ABE7H16R20
    1 X 11.197,58DZD = 11.197,58DZD
    ZB4BW041
    ZB4BW041
    1 X 3.425,03DZD = 3.425,03DZD
    NSYPFCX
    NSYPFCX
    1 X 2.335,87DZD = 2.335,87DZD
    LV432813
    LV432813
    1 X 102.715,28DZD = 102.715,28DZD
    18637
    18637
    1 X 28.995,85DZD = 28.995,85DZD
    ZB4BW0G43
    ZB4BW0G43
    1 X 2.074,10DZD = 2.074,10DZD
    A9C30811
    A9C30811
    1 X 2.007,41DZD = 2.007,41DZD
    9001KA3
    9001KA3
    1 X 1.662,54DZD = 1.662,54DZD
    A9F84204
    A9F84204
    1 X 5.852,07DZD = 5.852,07DZD