Référence : MVS40N3NW2A
Marque : Schneider
Disponibilité : En Stock
MVS40N3NW2A
EP MVS CB 4000A 55kA 3P EDO 240VAC ETA2
1.786.669,18DZD
Point de vente
- Garantie de remboursement sans risque !
- Remboursements sans tracas
Caractéristiques
MVS40N3NW2A
Characteristics
EP MVS CB 4000A 55kA 3P EDO 240VAC ETA2
drawout electrical circuit breaker
Main
Range of product EasyPact MVS
Range EasyPact
Product name MVS40N
Device short name MVS40N
Product or component type Circuit breaker
Device application Distribution
Poles description 3P
Protected poles description 3P 3d
Network type AC
Breaking capacity code N
Suitability for isolation Yes conforming to IEC 60947-2
Utilisation category Category B
Trip unit name ETA2I
Trip unit technology Electronic
Trip unit rating 4000 A (-5…70 °C)
Complementary
Network frequency 50/60 Hz
Control type Electrically operated
Mounting mode Drawout
Mounting support Base plate
Rail
Connection position Horizontal
Vertical
Location of connection Rear
[In] rated current 4000 A (40 °C)
[Ui] rated insulation voltage 1000 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 12 kV conforming to IEC 60947-2
Jun 12, 2017
1
Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
[Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
Circuit breaker CT rating 4000 A
Breaking capacity 55 kA (Icu) at 220…440 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service breaking capacity 55 kA (Ics) at 220…440 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability 20000 cycles (with maintenance) conforming to IEC 60947-2
10000 cycles (without maintenance) conforming to IEC 60947-2
Electrical durability 5000 cycles (without maintenance), category B at 440 V AC 50/60 Hz, conforming to IEC 60947-2
2500 cycles (without maintenance), category B at 690 V AC 50/60 Hz, conforming to IEC 60947-2
Connection pitch 115 mm (without spreader)
Contact position indicator Yes
[Icm] rated short-circuit making 121 kA (Icm) at 220…440 V AC 50/60 Hz conforming to IEC 60947-2
capacity
[Icw] rated short-time withstand current 42 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2
55 kA (1 s) at 220…440 V AC 50/60 Hz conforming to IEC 60947-2
30 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2
Trip unit protection functions LI
Protection type Instantaneous short-circuit protection
Overload protection (long time)
Fault indication Overload
Short-circuit
Internal fault
Long time pick-up adjstment type Ir Adjustable 9 settings
Long time pick-up adjustment range 0.4…1 x In
Long time delay adjustment type Adjustable 9 settings
[Tr] long-time delay adjustment 0.5…24 s (6 x Ir)
Thermal memory 20 minutes before and after tripping
Instantaneous pick-up adjustment type Adjustable 9 settings
Ii
Instantaneous pick-up adjustment 1.5…10 x Ir
range
Zone selective interlocking ZSI With
Display type Digital display
Type of measurement Current
Current sensor rating range 1000/4000 A
Maximum breaking time 25 ms
Closing response time < 70 ms
Height 439 mm
Width 441 mm
Depth 395 mm
Product weight 90 kg
Environment
Standards IEC 60947-2
Product certifications CCC
GOST
IEC
CCS
IP degree of protection IP40
Pollution degree 4 conforming to IEC 60664-1
Ambient air temperature for operation -5...70 °C
Ambient air temperature for storage -40...85 °C (without control unit)
-25...85 °C (with control unit)
Offer Sustainability
Sustainable offer status Green Premium product
RoHS (date code: YYWW) Compliant - since 1440 - Schneider Electric declaration of conformity
2
Schneider Electric declaration of conformity
REACh Reference not containing SVHC above the threshold
Reference not containing SVHC above the threshold
Product environmental profile Available
Product environmental
Product end of life instructions Available
End of life manual
Contractual warranty
Warranty period 18 months
3
Produits similaires
-
Masterpact NT et NW
MVS08N3MW2L
Note 0 sur 5676.288,73DZD Ajouter au panierEP MVS CB 800A 50KA 3P MDO ET2 DRAWOUT M
-
Masterpact NT et NW
MVS08N3NF2L
Note 0 sur 5574.521,38DZD Ajouter au panierEP MVS CB 800A 50KA 3P EF 240VAC ET2 FIX
-
Masterpact NT et NW
MVS08N3NW5A
Note 0 sur 5747.112,03DZD Ajouter au panierEP MVS CB 800A 50KA 3P EDO 240VAC ETA5 D
-
Masterpact NT et NW
MVS08H3MF6L
Note 0 sur 5540.148,31DZD Ajouter au panierEP MVS CB 800A 65KA 3P MF ET6 FIXED MANU
-
Masterpact NT et NW
MVS08N3MF5L
Note 0 sur 5500.864,80DZD Ajouter au panierEP MVS CB 800A 50KA 3P MF ET5 FIXED MANU
-
Masterpact NT et NW
MVS08N3MW6A
Note 0 sur 5725.442,73DZD Ajouter au panierEP MVS CB 800A 50KA 3P MDO ETA6 DRAWOUT
-
Masterpact NT et NW
MVS08H3NW6L
Note 0 sur 5863.185,06DZD Ajouter au panierEP MVS CB 800A 65KA 3P EDO 240VAC ET6 DR
-
Masterpact NT et NW
MVS08N3NF6L
Note 0 sur 5574.521,38DZD Ajouter au panierEP MVS CB 800A 50KA 3P EF 240VAC ET6 FIX