Nos marques

Tous les produits Schneider

Produits récemment consultés

LC1D258P7

10.433,10DZD

LC1D09ND

7.484,39DZD

LC1D18ED

9.051,81DZD

LC1D12BL

5.722,18DZD

MVS40N4MW6V

UGS : 2c33d16d423a Catégorie :
EP MVS CB 4000A 55kA 4P MDO ETV6 drawout

2.112.133,58DZD

UGS : 2c33d16d423a

Spécificités essentielles

Produits associés

Options et accessoires compatibles

Référence :

MVS40N4MW6V Marque : Schneider Disponibilité : En Stock



  • MVS40N4MW6V
  • Characteristics
  • EP MVS CB 4000A 55kA 4P MDO ETV6 drawout
  • manual Circuit breaker
  • Main
  • Range of product EasyPact MVS
  • Range EasyPact
  • Product name MVS40N
  • Device short name MVS40N
  • Product or component type Circuit breaker
  • Device application Distribution
  • Poles description 4P
  • Protected poles description 4P 4d
  • Neutral position Left
  • Network type AC
  • Breaking capacity code N
  • Suitability for isolation Yes conforming to IEC 60947-2
  • Utilisation category Category B
  • Trip unit name ETV6G
  • Trip unit technology Electronic
  • Trip unit rating 4000 A (-5...70 °C)
  • Complementary
  • Network frequency 50/60 Hz
  • Control type Manually operated
  • Mounting mode Drawout
  • Mounting support Base plate
  • Rail
  • Connection position Horizontal
  • Vertical
  • Location of connection Rear
  • [In] rated current 4000 A (40 °C)
  • [Ui] rated insulation voltage 1000 V AC 50/60 Hz conforming to IEC 60947-2
  • Jun 12, 2017
  • 1
  • Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
  • [Uimp] rated impulse withstand voltage 12 kV conforming to IEC 60947-2
  • [Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
  • Circuit breaker CT rating 4000 A
  • Breaking capacity 55 kA (Icu) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
  • [Ics] rated service breaking capacity 55 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
  • Mechanical durability 20000 cycles (with maintenance) conforming to IEC 60947-2
  • 10000 cycles (without maintenance) conforming to IEC 60947-2
  • Electrical durability 5000 cycles (without maintenance), category B at 440 V AC 50/60 Hz, conforming to IEC 60947-2
  • 2500 cycles (without maintenance), category B at 690 V AC 50/60 Hz, conforming to IEC 60947-2
  • Connection pitch 115 mm (without spreader)
  • Contact position indicator Yes
  • [Icm] rated short-circuit making 121 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
  • capacity
  • [Icw] rated short-time withstand current 42 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2
  • 55 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2
  • 30 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2
  • Neutral protection setting Without protection (3d)
  • 0.5 x Ir (3d + N/2)
  • 1 x Ir (4d)
  • Trip unit protection functions LSIG
  • Protection type Earth fault
  • Instantaneous short-circuit protection
  • Overload protection (long time)
  • Short time short-circuit protection
  • Fault indication Overload
  • Short-circuit
  • Internal fault
  • Earth fault
  • Long time pick-up adjstment type Ir Adjustable 9 settings
  • Long time pick-up adjustment range 0.4...1 x In
  • Long time delay adjustment type Adjustable 9 settings
  • [Tr] long-time delay adjustment 0.5...24 s (6 x Ir)
  • Short-time pick-up adjustment type Isd Adjustable 9 settings
  • [Isd] short-time pick-up adjustment 1.5...10 x Ir
  • range
  • Short-time delay adjustment type Adjustable 5 settings
  • [Tsd] short-time delay adjustment 100...400 ms
  • range
  • Instantaneous pick-up adjustment type Adjustable 9 settings
  • Ii
  • Instantaneous pick-up adjustment 2...15 x In
  • range Off
  • Ground-fault pick-up adjustment type Adjustable 9 settings
  • Ground-fault time delay adjustment Adjustable 5 settings
  • type -tg
  • [Tg] ground-fault time delay 100...400 ms
  • adjustment range
  • [Ig] ground-fault pick-up adjustment 500...1200 A
  • range
  • Zone selective interlocking ZSI With
  • Display type Digital display
  • Type of measurement Voltage
  • Current sensor rating range 1000/4000 A
  • Maximum breaking time 25 ms
  • Closing response time < 70 ms
  • Height 439 mm
  • Width 556 mm
  • Depth 395 mm
  • Product weight 120 kg
  • 2
  • Environment
  • Standards IEC 60947-2
  • Product certifications CCC
  • GOST
  • IEC
  • CCS
  • IP degree of protection IP40
  • Pollution degree 4 conforming to IEC 60664-1
  • Ambient air temperature for operation -5...70 °C
  • Ambient air temperature for storage -40...85 °C (without control unit)
  • -25...85 °C (with control unit)
  • Offer Sustainability
  • Sustainable offer status Green Premium product
  • RoHS (date code: YYWW) Compliant  - since  1440  -  Schneider Electric declaration of conformity
  • Schneider Electric declaration of conformity
  • REACh Reference not containing SVHC above the threshold
  • Reference not containing SVHC above the threshold
  • Product environmental profile Available
  • Product environmental
  • Product end of life instructions Available
  • End of life manual
  • Contractual warranty
  • Warranty period 18 months
  • 3

Produits Similaires

100 000 de références

Trouvez tout ce dont vous avez besoin dans notre catalogue

Livraison adaptée à vos besoins

Nos solutions de livraison fiables et rapides facilitent votre quotidien

Des conseils d’expert

Recevez une assistance technique de spécialistes pour soutenir vos projets

10
    10
    Votre panier
    schneider
    CA2KN22F72
    2 X 4.259,02DZD = 8.518,04DZD
    LC1D25SD
    LC1D25SD
    1 X 10.099,53DZD = 10.099,53DZD
    CA2KN22E7
    CA2KN22E7
    1 X 3.788,71DZD = 3.788,71DZD
    CA2KN22N7
    CA2KN22N7
    1 X 4.085,86DZD = 4.085,86DZD
    LC1D188R7
    LC1D188R7
    1 X 8.801,86DZD = 8.801,86DZD
    AB1GS
    AB1GS
    1 X 51,46DZD = 51,46DZD
    CA2KN22U7
    CA2KN22U7
    1 X 3.788,71DZD = 3.788,71DZD
    CA2KN22U72
    CA2KN22U72
    1 X 4.743,75DZD = 4.743,75DZD
    NSYCEP
    NSYCEP
    1 X 2.082,06DZD = 2.082,06DZD