Spécificités essentielles

Produits associés

Options et accessoires compatibles

Autres produits associés

Description du produit
Référence :

LV431977 Marque : Schneider Disponibilité : En Stock



  • LV431977
  • Characteristics
  • circuit breaker VigiCompact MH NSX250B -
  • Micrologic 2.2- 100 A - 3 poles 3d
  • Main
  • Range Compact
  • Product name Compact NSX
  • Product or component type Circuit breaker with Vigi module
  • Device short name VigiCompact NSX250B
  • Device application Distribution
  • Poles description 3P
  • Protected poles description 3t
  • Network type AC
  • Network frequency 50/60 Hz
  • [In] rated current 250 A ( 40 °C )
  • [Ui] rated insulation voltage 800 V AC 50/60 Hz
  • [Uimp] rated impulse withstand voltage 8 kV
  • [Ue] rated operational voltage 440 V AC 50/60 Hz
  • Breaking capacity code B
  • Breaking capacity 25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
  • 15 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
  • 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
  • 40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
  • 20 kA at 480 V AC 50/60 Hz conforming to NEMA AB1
  • 40 kA at 240 V AC 50/60 Hz conforming to NEMA AB1
  • [Ics] rated service breaking capacity Ics 15 kA 500 V AC 50/60 Hz conforming to IEC 60947-2
  • Ics 20 kA 440 V AC 50/60 Hz conforming to IEC 60947-2
  • Ics 25 kA 380/415 V AC 50/60 Hz conforming to IEC 60947-2
  • Ics 40 kA 220/240 V AC 50/60 Hz conforming to IEC 60947-2
  • Suitability for isolation Yes conforming to EN 60947-2
  • Yes conforming to IEC 60947-2
  • Utilisation category Category A
  • Trip unit name Micrologic 2.2
  • Trip unit technology Electronic
  • Trip unit protection functions LSoI
  • Jun 12, 2017
  • 1
  • Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
  • Trip unit rating 100 A ( 40 °C )
  • Protection type Instantaneous short-circuit protection
  • Overload protection (long time)
  • Short time short-circuit protection
  • Earth-leakage add-on module name MH
  • Pollution degree 3 conforming to IEC 60664-1
  • Complementary
  • Control type Toggle
  • Mounting mode Fixed
  • Mounting support Backplate
  • Upside connection Front
  • Downside connection Front
  • Mechanical durability 20000 cycles
  • Electrical durability 10000 cycles 440 V In conforming to IEC 60947-2
  • 10000 cycles 690 V In/2 conforming to IEC 60947-2
  • 20000 cycles 440 V In/2 conforming to IEC 60947-2
  • 5000 cycles 690 V In conforming to IEC 60947-2
  • Connection pitch 35 mm
  • Local signalling LED 105 % Ir
  • LED 90 % Ir
  • LED ready
  • Long time pick-up adjstment type Ir Adjustable 9 settings
  • Long time pick-up adjustment range 0.9...1 x Io
  • Long time delay adjustment type Fixed
  • [Tr] long-time delay adjustment 11 s 7.2 x Ir
  • 16 s 6 x Ir
  • 400 s 1.5 x Ir
  • Thermal memory 20 minutes before and after tripping
  • Short-time pick-up adjustment type Isd Adjustable 9 settings
  • [Isd] short-time pick-up adjustment 1.5...10 x Ir
  • range
  • Short-time delay adjustment type Fixed
  • Instantaneous pick-up adjustment type Fixed
  • Ii
  • Instantaneous pick-up adjustment 1500 A
  • range
  • Earth-leakage protection class Class A
  • Earth-leakage protection With
  • Residual earth-leakage sensitity Adjustable 5 settings
  • adjustment type
  • [Δt] residual earth-leakage sensitive 0.03...10 A
  • adjustment
  • Residual earth-leakage time delay Adjustable 4 settings
  • adjustment type
  • Height 236 mm
  • Width 105 mm
  • Depth 86 mm
  • Product weight 2.4 kg
  • Environment
  • Electrical shock protection class Class II
  • Standards EN 60947-2
  • IEC 60947-2
  • NEMA AB1
  • UL 508
  • Product certifications CSA
  • UL
  • 2
  • IP degree of protection IP40 conforming to IEC 60529
  • IK degree of protection IK07 conforming to IEC 62262
  • Ambient air temperature for operation -35...70 °C
  • Ambient air temperature for storage -55...85 °C
  • Offer Sustainability
  • Sustainable offer status Not Green Premium product
  • RoHS (date code: YYWW) Compliant  - since  0839  -  Schneider Electric declaration of conformity
  • Schneider Electric declaration of conformity
  • Product end of life instructions Need no specific recycling operations
  • Contractual warranty
  • Warranty period 18 months
  • 3

20 000 de références

Trouvez tout ce dont vous avez besoin dans notre catalogue

Livraison adaptée à vos besoins

Nos solutions de livraison fiables et rapides facilitent votre quotidien

Des conseils d’expert

Recevez une assistance technique de spécialistes pour soutenir vos projets

Panier